Time to development and imaging features of new calcifications in the treated breast after breast-conserving therapy
Lauren Q Chang Sen1, Annie Ko1, Miral M Patel1
1Department of Breast Imaging, The University of Texas MD Anderson Cancer Center, Houston, TX, USA.
Objective:
The purpose of our study was to analyze the time to development, malignancy rate, location, and mammographic features of new calcifications in the treated breast after breast-conserving therapy (BCT).
Materials And Methods:
In this HIPAA-complaint, IRB-approved retrospective study, we reviewed the records of patients treated with BCT at our institution with breast-conserving surgery performed between January 1, 2009 and December 31, 2010. A total of 735 breasts in 732 women were included in our study cohort. Factors analyzed included rate of development of new calcifications, malignancy rate of new calcifications, the time between completion of radiation therapy and development of new calcifications, imaging features of new calcifications, and location of the new calcifications in relation to the primary malignancy.
Results:
During follow-up, new calcifications developed in 155 of the 735 treated breasts (21.1%) and 155 of the 732 women (21.2%). After excluding two cases that were lost to follow-up, the malignancy rate of new calcifications was 5.2% (8/153; 95% CI: 2.3% to 10.0%). The median time to development of the benign calcifications was 27 months (range, 2 to 91 months) and of the malignant calcifications was 41 months (range, 11 to 57 months). Of the 20 (13.1%) cases of new calcifications categorized as BI-RADS 3 (probably benign), all were benign on follow-up (19 cases) or on biopsy (1 case). Of the 51 BI-RADS 4 (suspicious) cases, 8 (16%) were biopsy-proven malignant. The malignancy rate was the highest in fine pleomorphic 100% (1/1), followed by amorphous 17%, (5/29), coarse heterogeneous 8% (2/26) and typically benign 0 (0/97) calcifications (p < 0.0001). The malignancy rate was 1.5% (2/137) for new calcifications within the lumpectomy site vs. 37.5% (6/16) for new calcifications outside the lumpectomy site (p < 0.0001) and was 3.4% (5/147) for new calcifications at or within the same quadrant as the lumpectomy site vs. 50.0% (3/6) for new calcifications in a different quadrant from the lumpectomy site (p=0.002).
Conclusion:
Most new calcifications that developed in the treated breast after BCT were benign. Evaluation of morphology and distribution of those calcifications is imperative. New calcifications in the treated breast outside the lumpectomy site are more likely to be malignant and should be viewed with greater suspicion. Benign calcifications developed earlier than malignant calcifications, but the time courses overlapped.
More Related Videos
12:23Multi-modal Imaging of Angiogenesis in a Nude Rat Model of Breast Cancer Bone Metastasis Using Magnetic Resonance Imaging, Volumetric Computed Tomography and Ultrasound
Published on: August 14, 2012
12:57X-Ray Visualization of Intraductal Ethanol-Based Ablative Treatment for Prevention of Breast Cancer in Rat Models
Published on: December 9, 2022
Related Concept Videos
Radiological Investigation I: X-ray and CT
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...