Related Experiment Video
Updated: Oct 25, 2025

A Modified QuEChERS-HPLC Method for Detection of Polycyclic Aromatic Hydrocarbons in Zebrafish Embryos Exposed to Fine Particulate Matter
Published on: June 13, 2025
Measurement of polychlorinated biphenyls with hand wipes and matched serum collected from Chinese E-waste dismantling
Chen Zhao1, Ji-Fang-Tong Li2, Xing-Hong Li2
1State Key Laboratory of Environmental Chemistry and Ecotoxicology, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, PO Box 2871, 18 Shuangqing Road, Haidian District, Beijing 100085, PR China; College of Earth Sciences, Guilin University of Technology, Guilin 541006, PR China.
Abstract:
To date, dermal/hand-to-mouth exposure to chemicals in the e-waste recycling environment has not been sufficiently understood, and the importance of dermal absorption of chemicals in e-waste dismantling workers remains controversial. In this study, we utilized hand wipes and matched sera to characterize dermal/hand-to-mouth exposure to PCBs for e-waste dismantling workers, and potential effects on thyroid hormones were also assessed. PCB loadings in hand wipes varied from 0.829-265 ng wipe-1 (11.3-2850 ng m-2 wipe-1), with 37.2 ng wipe-1 (432 ng m-2 wipe-1) as the median value. Serum concentrations of PCBs ranged from 32.3-3410 ng g-1 lipid weight (lw) with 364 ng g-1 lw as the median value. Between wipes and sera, lower-chlorinated congeners (e.g. CB-28, -66, -74, -99,-105 and -118) showed significant associations (p < 0.01), but higher-chlorinated congeners (e.g. CB-138, -153, -156, -170, and -180) did not. These lower-chlorinated CBs were the major contributors to estimated dermal/hand-to-mouth average daily doses (ADDs) and the hazard index (HI). Correspondingly, their estimated contributions to serum levels by dermal absorption were also significant, with the contribution of CB-28 being as high as 21.4%. As a consequence, dermal absorption of some low-chlorinated congeners was a non-negligible route for e-waste dismantling workers. Although insignificant association was shown between serum PCBs and thyroid hormones, the potential health risk should be of concern due to the high levels of PCBs observed in workers' sera.
More Related Videos
05:47In Silico Modeling Method for Computational Aquatic Toxicology of Endocrine Disruptors: A Software-Based Approach Using QSAR Toolbox
Published on: August 28, 2019
07:26A Simple Method for Automated Solid Phase Extraction of Water Samples for Immunological Analysis of Small Pollutants
Published on: January 1, 2016