Related Experiment Video
Updated: Oct 25, 2025

Diffuse Reflectance Spectroscopy: Getting the Capillary Refill Test Under One's Thumb
Published on: December 2, 2017
Point-Of-Care Capillary Refill Technology Improves Accuracy of Peripheral Perfusion Assessment.
David C Sheridan1,2, Robert L Cloutier1, Ravi Samatham3
1Department of Emergency Medicine, Oregon Health & Science University, Portland, OR, United States.
A new non-invasive sensor improves capillary refill time (CRT) assessment, offering a more precise and repeatable method for evaluating peripheral perfusion compared to subjective clinical judgment.
Area of Science:
- Critical Care Medicine
- Biomedical Engineering
- Physiology
Background:
- Capillary refill time (CRT) is a standard bedside method for assessing peripheral perfusion.
- CRT aids in recognizing conditions like sepsis and guiding therapeutic interventions.
- Current manual CRT assessment by clinicians exhibits significant variability.
Purpose of the Study:
- To evaluate a novel non-invasive finger sensor for objective CRT measurement.
- To compare device-based CRT assessment with expert assessment and clinical provider assessment.
- To determine if new technology can enhance the precision and repeatability of CRT measurements.
Main Methods:
- Prospective, observational study conducted in intensive care and emergency departments.
- Utilized a non-invasive finger sensor to measure CRT.
- Compared device CRT measurements against trained research personnel (gold standard) and clinical providers.
Main Results:
- Device CRT showed a strong correlation (Pearson r=0.693) with research personnel CRT.
- Clinical provider CRT demonstrated a weaker correlation (Pearson r=0.359) with research personnel CRT.
- 89 pairs of measurements were analyzed.
Conclusions:
- Point-of-care technology offers a promising solution for improving peripheral perfusion assessment.
- Standardized CRT measurement via technology can enhance the translation of critical care research.
- Objective CRT assessment is crucial for emergency department triage and resuscitation efforts.
More Related Videos
Related Concept Videos
Assessment of radial pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps:
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...
Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above...
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
Peripheral Artery Disease IV: Nursing Management