Related Experiment Video
Updated: Oct 25, 2025

Cortical Bone Assessment Using Ultrasonic Guided Waves: A Reproducibility Study in a Healthy Population
Published on: January 31, 2025
Value of quantitative ultrasound and bioelectrical impedance analysis in detecting low bone mineral density in
Ting Xiang1, Li Zhou1, Ping Fu1
1Division of Nephrology, Kidney Research Institute, West China Hospital of Sichuan University, Chengdu, Sichuan, China.
Introduction:
Patients on maintenance hemodialysis (MHD) are highly predisposed to low bone mineral density (BMD). This study aims to assess the value of quantitative ultrasound (QUS), bioelectrical impedance analysis (BIA), and their combination in detecting high-risk patients for low BMD in MHD.
Methods:
Patients' BMD of the total hip, femoral neck, and lumbar spine were measured using dual-energy X-ray absorptiometry (DXA). Bone mineral content (BMC) was assessed using BIA. Calcaneal BMD was measured using QUS. Patients with a T-score of ≤-2.5 were recorded as 'low BMD.'
Results:
Overall, 93 subjects (62.37% female; mean age, 60.8 ± 16.2 years) were included in this cross-sectional study; approximately 36.56% met the 'low BMD' criteria. QUS-T score predicted low BMD with an area under the curve (AUC) value of 0.738, sensitivity of 70.59%, and specificity of 76.27%. The AUC for low BMD diagnosis using the BMC index (BMCI) measured through BIA was 0.679 (sensitivity, 91.18%; specificity, 38.98%). On the other hand, the combination of QUS-T score and BMCI yielded a higher AUC value of 0.762 with an improved specificity of 88.14%. Compared with the QUS and BIA alone, the net reclassification improvement (NRI) of the combination model increased by 47.16% (p = 0.022) and 78.36% (p < 0.0001), respectively. Integrated discrimination improvement (IDI) increased by 5.25% (p = 0.043) and 9.99% (p = 0.003), respectively. QUS-T score and BMCI were related to BMD independently assessed by DXA.
Conclusion:
The combination of QUS and BIA is effective in screening for low BMD among MHD patients.
Related Concept Videos
Hemodialysis III: Nursing Management
Chronic Kidney Disease III: Interprofessional Care
Hemodialysis II: Procedure and Complications
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Imaging Studies II: Ultrasonography
Drug Dosing in Renal Diseases: Estimation of Glomerular Filtration Rate Based on Serum Creatinine Concentration

