Transcatheter mechanical thrombectomy of neonatal occlusive aortic thrombus using an Amplatzer Piccolo PDA occluder
Christopher Herron1,2, Stuart Covi3, Athina Pappas4,5
1Division of Cardiology, Children's Hospital of Michigan, Detroit, MI, USA.
Abstract:
Neonatal aortic thrombus is a rare and critical condition that can present mimicking severe coarctation of the aorta or interrupted aortic arch. Transcatheter thrombectomy for this lesion has not been well described. We report a premature neonate with an occlusive proximal descending aorta thrombus, who underwent transcatheter mechanical thrombectomy using an Amplatzer Piccolo PDA occluder (Abbott, North Chicago, IL, USA). The procedure was successful with no subsequent distal thromboembolic events.