Related Experiment Video
Updated: Oct 25, 2025

Bacterial Detection & Identification Using Electrochemical Sensors
Published on: April 23, 2013
Heteroditopic chemosensor to detect γ-hydroxybutyric acid (GHB) in soft drinks and alcoholic beverages
Silvia Rodríguez-Nuévalos1, Margarita Parra1,2,3, Salvador Gil1,2,3
1Instituto Interuniversitario de Investigación de Reconocimiento Molecular y Desarrollo Tecnológico (IDM). Universitat Politècnica de València, Universitat de València, Doctor Moliner 50, Burjassot, 46100, Valencia, Spain. ana.costero@uv.es.
Abstract:
Drug-Facilitated Sexual Assault (DFSA) is a problem of considerable dimensions on a global scale. Among the different compounds used in DFSA assaults, 4-hydroxybutyric acid (GHB) is one of the most elusive due to its physical and biological characteristics. Therefore, the development of real-time detection methods to detect GHB not only in drinks but also in urine is very important for personal and social security. Here, we report two new heteroditopic chemosensors capable of recognizing and detecting GHB in soft drinks, alcoholic beverages and synthetic urine. The compounds have two moieties: a trifluoroacetyl group and a thiourea, which are able to interact respectively with the hydroxyl and the carboxylic groups present in the GHB structure. In addition, the distance between these two groups has been optimized to allow a double interaction which guarantees the recognition even in very competitive media such as beverages or urine samples.
Related Concept Videos
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Gas Chromatography: Types of Detectors-II
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
High-Performance Liquid Chromatography: Types of Detectors
IR and UV–Vis Spectroscopy of Carboxylic Acids
However, the stretching absorptions for the C=O bond vary depending on the structure of carboxylic acids. The C=O bond of the free carboxylic acids shows a higher stretching frequency, 1760 cm−1, while H-bonded carboxylic acids (dimers) exhibit stretching absorptions at a lower frequency,...
¹H NMR Chemical Shift Equivalence: Enantiotopic and Diastereotopic Protons
In chiral compounds such as 2-butanol, replacing the methylene hydrogens at C3 produces a pair of...

