Herein, a new gas-cycle-assisted (GCA) headspace solid-phase microextraction (HS-SPME) device was designed to rapidly extract organic pollutants with high Kow and boiling points, which have difficulty in volatilization from matrix to headspace. Organic pollutants, including three polycyclic aromatic hydrocarbons (PAHs), four polychlorinated biphenyls (PCBs), and five phthalate esters (PAEs), were selected to evaluate the performance of GCA HS-SPME. Compared with conventional HS-SPME, the equilibrium times of GCA HS-SPME for extraction of PAHs, PCBs, and PAEs were greatly shortened from 70-90 to 5-11 min. Moreover, the limits of detection for analysis of PAHs were achieved at pg mL-1 level by GCA HS-SPME coupled with gas chromatography-flame ionization detection.
More Related Videos
09:19Capturing Actively Produced Microbial Volatile Organic Compounds from Human-Associated Samples with Vacuum-Assisted Sorbent Extraction
Published on: June 1, 2022
11:44Qualitative Characterization of the Aqueous Fraction from Hydrothermal Liquefaction of Algae Using 2D Gas Chromatography with Time-of-flight Mass Spectrometry
Published on: March 6, 2016
Related Concept Videos
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
Gas Chromatography: Types of Detectors-II
Gas Chromatography: Sample Injection Systems
Two primary injection methods are used...
Gas Chromatography: Overview of Detectors