Related Experiment Video
Updated: Oct 24, 2025

Magnetic Resonance Imaging of Multiple Sclerosis at 7.0 Tesla
Published on: February 19, 2021
Magnetic resonance imaging safety in patients with cardiac implantable electronic devices
Eunice Yang1, Masahito Suzuki2, Saman Nazarian3
1Department of Medicine, Division of Cardiology, Johns Hopkins Hospital, Baltimore, MD, United States.
Abstract:
High strength magnetic and electric fields used in magnetic resonance imaging (MRI) render images with unmatched soft tissue contrast. These imaging attributes have made MRI an increasingly preferred diagnostic tool in many medical conditions. Initially there was substantial concern regarding the safety of performing these imaging studies in patients with cardiac implantable electronic devices (CIEDs), which have the potential to be affected by the intense electric and magnetic fields of the MRI. More recently, there has been increasing evidence that MRI can be performed safely in patients with devices that have not been specifically labelled by regulatory agencies for use in an MRI environment (MRI nonconditional devices), which has allowed the Centers for Medicare and Medicaid Services (CMS) to start providing reimbursement for MRIs of patients with MRI nonconditional devices. For CMS to reimburse scans, a rigorous protocol must be followed, which recognizes that there are still potential adverse effects that can be mitigated by appropriate procedures. In this review we will survey the initial experiences and efforts to understand the magnitude of risk for device malfunction and harm, as well as current efforts to minimize the potential risks of MRI effects on devices and leads (heating, device movement, lead dislodgement, and device malfunction, the latter including inhibition of pacing and generation of arrhythmias).
Related Concept Videos
Imaging Studies for Cardiovascular System IV: CMRI
Magnetic Resonance Imaging
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies IV: Magnetic Resonance Imaging
Imaging Studies for Cardiovascular System V: CT
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...

