Related Experiment Video
Updated: Oct 24, 2025

Full-root Aortic Valve Replacement by Stentless Aortic Xenografts in Patients with Small Aortic Roots
Published on: May 21, 2017
Aortic root replacement with Medtronic Freestyle bioprosthesis: 25-year experience
Joseph C Sweeney1, Susan A Smith1, Divya Avula2
1Department of General Surgery, University of Louisville, Louisville, Kentucky, USA.
Background:
Stentless porcine bioprothesis is a surgical strategy to treat aortic root disease. Use has been limited due to the concern for long-term valve degeneration. This study evaluated the perioperative and late outcomes of patients with aortic root disease requiring root replacement.
Methods:
A total of 409 patients underwent aortic root replacement by a single surgeon using a stentless porcine bioroot between February 1996 and May 2020. The cohort was divided into two groups (age ≤65 and >65 years). Descriptive statistics were used to analyze the data and Kaplan-Meier curves used to evaluate long-term outcomes.
Results:
Patients age >65 years were more likely to be female (p = .01), have hypertension (p = .01), require circulatory arrest (p = .01), and have concomitant coronary artery bypass grafting (CABG) (p = .04). Baseline creatinine >1.8 (p = .20), diabetes (p = .06), and ejection fraction (p = .20) were similar between groups. The 1-, 5-, and 10-year survival for patients age ≤65 years were 92%, 87%, and 69%, respectively, significantly better than patients age >65 (88%, 73%, and 43%, respectively) (p < .01, Figure 1). The 1-, 5-, and 10-year freedom from reoperation for patients ≤65 years were 99%, 97%, and 93% versus 99%, 98%, and 96% in patients age >65 years, respectively (p = .24).
Conclusion:
Patients with aortic root disease can be treated with acceptable perioperative outcomes, long-term survival, and low reoperation rates using a stentless porcine bioprothesis. It should be considered irrespective of age due to its excellent durability and freedom from anti-coagulation requirement.
More Related Videos
14:14Standardized Technique of Aortic Valve Re-implantation for Valve-sparing Aortic Root Replacement
Published on: December 11, 2017
05:31Transcatheter Pulmonary Valve Replacement from Autologous Pericardium with a Self-Expandable Nitinol Stent in an Adult Sheep Model
Published on: June 8, 2022
Related Concept Videos
Aortic Regurgitation III: Medical Management
Mitral Stenosis III: Medical Management
Mitral Stenosis I: Introduction