Related Experiment Video
Updated: Oct 24, 2025

Four-Dimensional Computed Tomography-Guided Valve Sizing for Transcatheter Pulmonary Valve Replacement
Published on: January 20, 2022
Computed tomography measured psoas muscle attenuation predicts mortality after transcatheter aortic valve
Jeroen Walpot1,2, Paul Van Herck1, Valerie Collas3
1Department of Cardiology, University Hospital Antwerp, Antwerp -Edegem, Belgium.
Aims:
The aim of this study was to determine if computed tomography (CT) psoas muscular attenuation measurements may predict all-cause mortality in patients undergoing TAVI.
Methods:
Ninety-four consecutive patients undergoing TAVI were analysed. The CT axial slice at the level of the fourth lumbar vertebra was selected. The psoas muscle areas were manually contoured. The circumferential surface area (CSA) of both psoas muscles was determined by selecting the voxels with attenuation values, ranging from 0 to 100 Hounsfield Units (HU). The mean CT attenuation coefficient of the psoas muscle (Psoas mean HU) was measured. The muscle was subdivided into a low-density muscle (LDM) (0-29 HU) and high-density muscle (HDM) (30-100 HU) portion. The HDM/LDM ratio was calculated. We searched for a correlation between HDM/LDM, CSA LDM (%), Psoas mean HU and all-cause mortality.
Results:
The mean age was 81.2 ± 7.5 years. Thirty patients had adverse outcome (all-cause mortality). Compared with patients with the lowest CSA LDM (%), patients in the third and second tertiles had an increased hazard ratio for mortality (2.871; 95% confidence interval 0.880-9.371 and 5.044; 95% confidence interval 1.641-15.795, respectively) in a multivariable model with EuroSCORE II, Barthel frailty index and CSA LDM (%) (P = 0.231, 0.097 and 0.019, respectively). HDM/LDM and Psoas mean HU (as continuous variable) were also independent predictors of all-cause mortality (P = 0.019, P = 0.013, respectively).
Conclusion:
CSA LDM (%), Psoas mean HU and HDM/LDM are independent and incremental predictors of all-cause mortality in patients undergoing TAVI.
More Related Videos
06:59Improved Registration of 3D CT Angiography with X-ray Fluoroscopy for Image Fusion During Transcatheter Aortic Valve Implantation
Published on: June 3, 2018
09:32Time-Resolved, Dynamic Computed Tomography Angiography for Characterization of Aortic Endoleaks and Treatment Guidance via 2D-3D Fusion-Imaging
Published on: December 9, 2021
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Imaging Studies III: Computed Tomography