In this study, a response surface methodology (RSM) approach using central composite design (CCD) was investigated to develop a mathematical model and to optimize the effects of pH, adsorbent amount and temperature related to the hexavalent chromium removal by biosorption on peanut shells (PSh). The highest removal percentage of 30.28% was found by the predicted model under the optimum conditions (pH of 2.11, 0.73 g of PSh and 37.2 °C) for a 100 mg/L initial Cr(VI) concentration, which was very near to the experimental value (29.92%). The PSh was characterized by SEM, EDX, FTIR, BET, XRD analyses. Moreover, a Langmuir isotherm fitted well (R2 = 0.992) with the experimental data, and the maximum adsorption capacity was discovered to be 2.48 and 3.49 mg/g respectively at 25 and 45 °C. Kinetic data were well foreseen by pseudo second order. Thermodynamic study depicted that biosorption of Cr(VI) onto PSh was spontaneous and endothermic. Regeneration of the PSh using NaOH showed a loss <5% in the Cr(VI) removal efficiency up to three recycle runs. In summary, the Cr(VI) removal onto economic, sensitive and selective biosorbent (PSh) was optimized using CCD to study biosorption behaviors.
Related Concept Videos
Microbial Bioremediation of Uranium
Microbial Bioremediation of Pesticides
Methods of Medium Optimization
Biological Treatment of Effluent and Waste Water