Related Experiment Video
Updated: Oct 24, 2025

Autonomic Function Following Concussion in Youth Athletes: An Exploration of Heart Rate Variability Using 24-hour Recording Methodology
Published on: September 21, 2018
Assessment of a Novel, 22-lead Mobile Electrocardiogram in Elite, Adolescent Footballers
Harvey Johnson1, Nuno Duarte2, Diane Ryding3
1Bristol Medical School, University of Bristol, Bristol, United Kingdom of Great Britain and Northern Ireland.
Abstract:
The 12-lead electrocardiogram is a key component of cardiac screening in elite adolescent footballers. Current technology hampers mobile electrocardiogram monitoring that could reduce the time-to-diagnosis in symptomatic athletes. Recently, a 22-lead mobile electrocardiogram monitor, CardioSecur (Personal MedSystems GmbH), has been approved for use in adults. In this study, the differences in parameter accuracy between CardioSecur's 22-lead electrocardiogram and the gold standard 12-lead electrocardiogram were assessed in elite adolescent footballers (n=31) using Bland-Altman and paired t-tests/Wilcoxon analysis. Agreement between the two devices was clinically acceptable for heart rate (bias=- 0.633 bpm), PR Interval (bias=- 1.73 ms), Bazzett's corrected QTc interval (bias=2.03 ms), T-wave axis (bias=6.55°), P-wave duration (bias=- 0.941 ms), Q-wave amplitude (bias=0.0195 mV), Q-wave duration (bias=1.98 ms), rhythm (bias=0.0333), ST-segment (bias=- 0.0629), J-point analysis (bias=- 0.01) and extended T wave and QRS duration analysis. Unsatisfactory agreement was observed in QRS axis (bias=- 19.4°), P-wave axis (bias=- 0.670°), QRS amplitude (bias=- 0.660 mV), P-wave amplitude (bias=0.0400 mV) and T-wave amplitude (bias=- 0.0675 mV). CardioSecur's 22-lead electrocardiogram agrees with the gold standard in rhythm, durations, T-wave determination in all leads assessed, permitting its use in adolescent footballers for immediate pitch- or track-side analysis.
Related Concept Videos
Electrocardiogram
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and...
Electrocardiogram Fundamentals
An electrocardiogram (ECG) is a diagnostic tool for identifying cardiac conditions such as arrhythmias, conduction abnormalities, and myocardial ischemia.
Definition
An electrocardiogram (ECG) visualizes the heart's electrical activity by tracing the electrical movement associated with each heartbeat on a graph or monitor. As the heart beats, an electrical wave passes through it, correlating with the cardiac cycle events.
Parts of an ECG
An ECG utilizes electrodes on the skin...
Exercise Stress Test
Exercise stress testing, commonly known as a treadmill test, is a noninvasive procedure used to evaluate cardiovascular function and diagnose heart conditions.
Definition
An exercise stress test measures the heart's response to exertion using a treadmill or stationary bicycle. Chest electrodes record the heart's electrical activity through an ECG, and blood pressure is monitored regularly.
Purposes
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
Dysrhythmias V: Evaluating Dysrhythmias
Assessment of apical pulse
Assessing the apical pulse is a critical nursing procedure, particularly indicated for: