Clean Sampling and Analysis of River and Estuarine Waters for Trace Metal Studies
Published on: July 1, 2016
Time-series sampling of trace metals in surface waters using osmotic sampler with air segmentation and preservative
Quanlong Li1, Junxian Pei1, Bingyan Lu1
1State Key Laboratory of Marine Environmental Science, Fujian Provincial Key Laboratory for Coastal Ecology and Environmental Studies, College of the Environment & Ecology, Xiamen University, 361102 Xiamen, China.
Abstract:
High-resolution time-series concentrations (CTS) are very important for the investigation of the biogeochemical processes of trace metals in the aquatic environment. However, the acquisition of CTS of trace metals in water is still challenging because of the lack of suitable samplers. In this study, an osmotic sampler coupled with air segment injection and preservative addition was employed for time-series sampling of trace metals in surface waters. In the sampler, water sampling and preservative adding are both driven by osmotic pumps (OPs), while air segment injection is accomplished by a timer-controlled micro diaphragm pump. During deployment, the sampling OP continuously draws water through a filter and stores it in a narrow-bore coil. Simultaneously, a preservative OP slowly pushes 30% HNO3 (v/v) into the collected sample for in situ preservation. Periodically, the micro diaphragm pump injects air into the continuous water stream to divide it into water segments, enabling accurate time-stamping. After retrieval, the time-series samples were pumped out from the coil and re-collected to analyze the CTS of analytes. The sampler was deployed in river, reservoir, and marine waters for 26 h and one week to measure CTS of trace metals at time resolutions of 2 h and 12 h. Results showed that the recoveries of a preloaded standard mixture (1.0 μg/L) in all samplers ranged from 93.1% to 117.8%. The measured CTS of Cd, Co, Cr, Cu, Mn, and Ni in the waters only varied in small ranges. Accordingly, the measured CTS data from the sampler were consistent with the obtained concentrations from grab sampling. The relative percent differences between the measurements from two samplers were less than 37.4%. These results demonstrate the reliability and accuracy of the sampler for time-series sampling of the chosen trace metals in surface waters.
Related Concept Videos
Sampling Methods: Sample Types
Solid samples include a variety of substances, such as sediments from water bodies, soil, metals, and biological tissues. Two standard methods for extracting sediments from water bodies are grab sampling and piston coring. Grab sampling involves using a device to collect a discrete sediment sample from the bottom of a water body with minimal disturbance. Grab samples do not always represent the entire area due to...
Precipitation and Co-precipitation
Preparation of Samples for Electron Microscopy