Prognostic Value of Peak Oxygen Uptake in Patients Supported With Left Ventricular Assist Devices (PRO-VAD)
Kiran K Mirza1, Mariusz K Szymanski2, Thomas Schmidt3
1Department of Cardiology, Rigshospitalet, Copenhagen, Denmark.
Objectives:
The purpose of this study was to examine whether peak oxygen uptake (pVO2) and other cardiopulmonary exercise test (CPET)-derived variables could predict intermediate-term mortality in stable continuous flow LVAD recipients.
Background:
pVO2 is a cornerstone in the selection of patients for heart transplantation, but the prognostic power of pVO2 obtained in patients treated with a left ventricular assist device (LVAD) is unknown.
Methods:
We collected data for pVO2 and outcomes in adult LVAD recipients in a retrospective, multicenter study and evaluated cutoff values for pVO2 including: 1) values above or below medians; 2) grouping patients in tertiles; and 3) pVO2 ≤14 ml/kg/min if the patient was not treated with beta-blockers (BB) or pVO2 ≤12 ml/kg/min if the patient was taking BB therapy.
Results:
Nine centers contributed data from 450 patients. Patients were 53 ± 13 years of age; 78% were male; body mass index was 25 ± 5 kg/m2 with few comorbidities (stroke: 11%; diabetes: 18%; and peripheral artery disease: 4%). The cause of heart failure (HF) was most often nonischemic (66%). Devices included were the HeartMate II and 3 (Abbott); and Heartware ventricular assist devices Jarvik and Duraheart (Medtronic). The index CPET was performed at a median of 189 days (154-225 days) after LVAD implantation, and mean pVO2 was 14.1 ± 5 ml/kg/min (47% ± 14% of predicted value). Lower pVO2 values were strongly associated with poorer survival regardless of whether patients were analyzed for absolute pVO2 in ml/kg/min, pVO2 ≤12 BB/14 ml/kg/min, or as a percentage of predicted pVO2 values (P ≤ 0.001 for all). For patients with pVO2 >12 BB/14 and ventilation/carbon dioxide relationship (VE/VCO2) slope <35, the 1-year survival was 100%.
Conclusions:
Even after LVAD implantation, pVO2 has prognostic value, similar to HF patients not supported by mechanical circulatory support devices. (PROgnostic Value of Exercise Capacity Measured as Peak Oxygen Uptake [pVO2] in Recipients of Left Ventricular Assist Devices [PRO-VAD]; NCT04423562).
More Related Videos
07:41Insertion, Maintenance, and Removal of the Percutaneous Dual Lumen Cannula Right Ventricular Assist Device
Published on: July 20, 2022
03:40Point-of-Care Ultrasound for Peripheral Veno-Arterial Extracorporeal Membrane Oxygenation Without Left Ventricular Venting
Published on: January 17, 2025
Related Concept Videos
Treatment for Pulmonary Arterial Hypertension: Oxygen Therapy for Respiratory Failure
Oxygen therapy is vital in increasing and maintaining blood oxygen levels in PAH patients. As a result, it aids in reducing fatigue,...
Heart Failure VI: Adjunct Therapies
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...
Chronic Obstructive Pulmonary Disease-IV: Assessement and Diagnostic Studies
Medical History
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...
Pulmonary Function Tests
Pulmonary Function Tests are crucial diagnostic tools for assessing respiratory function, particularly in patients with chronic respiratory disorders. They comprehensively evaluate lung volumes, ventilatory function, breathing mechanics, diffusion, and gas exchange. These tests help diagnose pulmonary diseases and play a significant role in monitoring disease progression, evaluating disability, and assessing response to therapy.
PFTs involve using a spirometer, a...