Related Experiment Video
Updated: Oct 24, 2025

08:45
Assessment of Physical Activity Intensity with Accelerometers and Oxygen Consumption
Published on: June 20, 2025
258
Influence of Accelerometer Calibration Approach on Moderate-Vigorous Physical Activity Estimates for
Charles E Matthews1, Sarah K Keadle1, David Berrigan2
1Metabolic Epidemiology Branch, Division of Cancer Epidemiology and Genetics, National Cancer Institute, Rockville, MD.
Medicine and Science in Sports and Exercise
|August 16, 2021
Abstract
No abstract available in PubMed .
Related Concept Videos
Measuring Acceleration Due to Gravity
868
Consider a coffee mug hanging on a hook in a pantry. If the mug gets knocked, it oscillates back and forth like a pendulum until the oscillations die out.
A simple pendulum can be described as a point mass and a string. Meanwhile, a physical pendulum is any object whose oscillations are similar to a simple pendulum, but cannot be modeled as a point mass on a string because its mass is distributed over a larger area. The behavior of a physical pendulum can be modeled using the principles of...
A simple pendulum can be described as a point mass and a string. Meanwhile, a physical pendulum is any object whose oscillations are similar to a simple pendulum, but cannot be modeled as a point mass on a string because its mass is distributed over a larger area. The behavior of a physical pendulum can be modeled using the principles of...
868
Variation in Acceleration due to Gravity near the Earth's Surface
2.5K
An object's apparent weight is its weight measured by a spring balance at its location. It is different from its true weight, the force with which the Earth pulls it, because of the Earth's rotation. Mathematically, an object's apparent weight equals its true weight minus the centripetal force that keeps it in a circular motion along with the Earth's surface every 24 hours.
The difference between the true and apparent weights is proportional to the square of the Earth's...
The difference between the true and apparent weights is proportional to the square of the Earth's...
2.5K
Relative Motion Analysis - Acceleration
508
A slider-crank mechanism converts rotational motion from the crank into linear motion of the slider or vice versa. This mechanism consists of three main parts: the crank, the connecting rod, and the slider. The movement of the slider-crank is an example of general plane motion as the fluctuating angle between the crank and the connecting rod. Consider a segment AB where point A is at the end of the slider and point B is on the diametrically opposite end to point A, on a crack. The variance in...
508
Calibration Curves: Correlation Coefficient
3.3K
In a linear calibration curve, there is a value called the calibration coefficient, denoted by 'r,' which measures the strength and the direction of association between two variables. The correlation coefficient value ranges from −1 to +1. A value of +1 indicates a perfect positive linear correlation, −1 denotes a perfect negative correlation, and 0 implies no correlation between the two variables. A positive correlation value establishes that as one variable increases, the...
3.3K
Relative Motion Analysis using Rotating Axes - Acceleration
457
Consider a component AB undergoing a linear motion. Along with a linear motion, point B also rotates around point A. To comprehend this complex movement, position vectors for both points A and B are established using a stationary reference frame. The absolute velocity of point B is determined by adding the absolute velocity of point A, the relative velocity of point B in the rotating frame, and the effects caused by the angular velocity within the rotating frame.
Time differentiation is...
Time differentiation is...
457
Calibration Curves: Linear Least Squares
3.3K
A calibration curve is a plot of the instrument's response against a series of known concentrations of a substance. This curve is used to set the instrument response levels, using the substance and its concentrations as standards. Alternatively, or additionally, an equation is fitted to the calibration curve plot and subsequently used to calculate the unknown concentrations of other samples reliably.
For data that follow a straight line, the standard method for fitting is the linear...
For data that follow a straight line, the standard method for fitting is the linear...
3.3K

