Related Experiment Video
Updated: Oct 23, 2025

Point-Of-Care Ultrasound Screening for Proximal Lower Extremity Deep Venous Thrombosis
Published on: February 10, 2023
D-dimer level for ruling out peripherally inserted central catheter-associated upper extremity deep vein thrombosis
Wanli Liu1,2, Lianxiang He1,2, Wenjing Zeng2,3
1Teaching and Research Section of Clinical Nursing, Xiangya Hospital of Central South University, Xiangya Hospital, Central South University, Changsha, China.
Aims:
To examine the effectiveness of D-dimer values to be used as an independent diagnostic marker for excluding peripherally inserted central catheter-associated upper extremity deep vein thrombosis and superficial vein thrombosis.
Design:
This was a retrospective case-cohort study.
Methods:
Records were reviewed for 281 patients who underwent peripherally inserted central catheter insertion between 1 October 2017 and 1 October 2019. According to the modified Wells score after peripherally inserted central catheter insertion, the patients who had low vein thrombosis risk underwent a D-dimer test and colour Doppler ultrasound.
Results:
Among 281 patients, 180 patients (64%, 95% CI: 58.2%-69.4%) had negative D-dimer results and 39 of 180 patients had vein thrombosis despite having a negative D-dimer result, resulting in a failure rate of 21.7% (95% CI: 16.3%-28.3%). The negative predictive value of peripherally inserted central catheter-associated vein thrombosis in the cancer group (80.0%, 95% CI: 73.2%-85.4%) was higher than that of the non-cancer group (60.0%, 95% CI: 35.7%-80.2%). The negative predictive value of peripherally inserted central catheter-associated deep venous thrombosis (84.9%, 95% CI: 78.7%-89.6%) was lower than that of the PICC-associated superficial venous thrombosis (91.0%, 95% CI: 85.4%-94.6%).
Conclusion:
The D-dimer levels maybe should not be used as a diagnostic index to rule out peripherally inserted central catheter-associated upper extremity vein thrombosis.
Related Concept Videos
Venous Thrombosis II: Clinical Manifestations and Diagnostic Studies
Venous Thrombosis III: Interprofessional Care
Venous Thrombosis IV: Nursing Management
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above...
Venous Thrombosis I: Introduction
Pulmonary Embolism II: Diagnostic Studies and Interprofessional Care