Related Experiment Video
Updated: Oct 23, 2025

Curtain Flow Column: Optimization of Efficiency and Sensitivity
Published on: June 12, 2016
Testing experimental designs in liquid chromatography (II): Influence of the design geometry on the prediction
A Gisbert-Alonso1, J A Navarro-Huerta1, J R Torres-Lapasió1
1Department of Analytical Chemistry, Faculty of Chemistry, Universitat de València, C/ Dr. Moliner 50, 46100 Burjassot, Spain.
Abstract:
In liquid chromatography, the reliability of predictions carried out with retention models depends critically on the quality of the training experimental design. The search of the best design is more complex when gradient runs are used instead of isocratic experiments. In Part I of this work (JCA 1624 (2020) 461180), a general methodology based on the error propagation theory was developed and validated for assessing the quality of training designs involving gradients. The treatment relates the mathematical properties of a retention model with the geometry of the training designs and their subsequent predictions. In that work, only five usual designs were considered. Part II investigates in detail the effects on predictions when the features of the training design (number and distribution of the experiments, initial and final modifier content, gradient slope(s), and location of gradient nodes and pulses) are varied systematically. Several groups of related designs containing one or more isocratic steps, linear or multi-linear gradients, or mixed isocratic/gradient runs, among others (in total 38 designs) were evaluated. Box and whiskers and triple plots of expected relative uncertainties were used to evidence the differences in prediction performance. The purpose was to give recommendations to construct designs with good prediction performance. The best designs sample (considering all runs) concentrations as diverse as possible, at any gradient time.
More Related Videos
20:24Characterization of Complex Systems Using the Design of Experiments Approach: Transient Protein Expression in Tobacco as a Case Study
Published on: January 31, 2014
10:21Automated Hydrophobic Interaction Chromatography Column Selection for Use in Protein Purification
Published on: September 21, 2011
Related Concept Videos
Chromatographic Methods: Terminology
Silica Gel Column Chromatography: Overview
Polar components tend to bind strongly to the silica gel, causing them to move slowly through the column. In contrast, nonpolar compounds...
Chromatographic Resolution
The effectiveness of separation can be evaluated by determining the level of separation between two neighboring peaks in a chromatogram, which represents the individual components of a sample.
In chromatography,...
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
Optimizing Chromatographic Separations
Band broadening refers to spreading solute bands as they travel through the column. This broadening can impact resolution. Plate height (H) represents the length required for one theoretical plate. A lower plate height corresponds to...
High-Performance Liquid Chromatography: Instrumentation