Related Experiment Video
Updated: Oct 23, 2025

Electrophysiological Assessment of Murine Atria with High-Resolution Optical Mapping
Published on: February 22, 2018
The relationship between anatomy and electrical parameters in His bundle pacing: A transthoracic echocardiography
Giovanni Coluccia1, Jacopo Senes1, Serena Corallo1
1Department of Cardiology, Ospedali del Tigullio, Via Don Bobbio, 25 - 16033 Lavagna (GE), Italy.
Purpose:
The implantation site of the His bundle (HB) lead may influence pacing parameters. Our aim was to characterize the anatomical location of the HB lead tip and its relationship with acute electrical parameters.
Methods:
Consecutive patients who underwent HB lead implantation, guided by standard fluoroscopy and electrophysiology, were prospectively enrolled. The relationship between HB lead tip and tricuspid valve plane (TVP) was assessed with post-procedure transthoracic echocardiography.
Results:
Twenty-five patients were studied. In 11 patients (44%), the HB lead tip did not cross the TVP (A group): in 7 cases it was screwed in the right atrium at a mean distance of -6.1 mm from the TVP and, in 4 cases, at the level of the tricuspid annulus. In the remaining 14 patients (56%), the lead tip crossed the TVP (V group): it was screwed in the right ventricle at a mean distance of 9.3 mm from the TVP. A and V groups had comparable HB capture thresholds (1.6 ± 1 V vs 1.7 ± 0.7 V, 1 ms pulse-width; p = 0.66); selective HB capture was significantly more represented in the A group (91% vs 21%; p = 0.001). Significantly higher R-wave amplitudes were seen in the V group (6.7 ± 3 vs 2.5 ± 1.7 mV; p = 0.0004), and they positively correlated with the distance from the TVP (p = 0.0038). Atrial oversensing was never observed.
Conclusion:
In a consecutive cohort of HB pacing recipients, the rate of patients who had an effective HB capture in the atrium was substantial and was characterized by different electrophysiological properties than in the ventricle.
Related Concept Videos
Electrocardiogram Fundamentals
An electrocardiogram (ECG) is a diagnostic tool for identifying cardiac conditions such as arrhythmias, conduction abnormalities, and myocardial ischemia.
Definition
An electrocardiogram (ECG) visualizes the heart's electrical activity by tracing the electrical movement associated with each heartbeat on a graph or monitor. As the heart beats, an electrical wave passes through it, correlating with the cardiac cycle events.
Parts of an ECG
An ECG utilizes electrodes on the skin...
Electrocardiogram
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and...
Dysrhythmias V: Evaluating Dysrhythmias
Imaging Studies for Cardiovascular System I:Echocardiography
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion,...
Correlation between ECG and Cardiac Cycle
A cardiac action potential originates in the SA node and spreads throughout the atria and the AV node in approximately 0.03 seconds. This results in the P wave in an ECG and triggers atrial contraction. The action potential is then briefly slowed at the AV node, allowing the atria to contract and fill the ventricles with blood before...