Related Experiment Video
Updated: Oct 23, 2025

Safety Precautions and Operating Procedures in an ABSL-4 Laboratory: 4. Medical Imaging Procedures
Published on: October 3, 2016
Establishing ionising radiation safety culture during interventional cardiovascular procedures
1Department of Clinical Sciences, Faculty of Health and Environmental Sciences, Central University of Technology Free State, Bloemfontein, South Africa.
Introduction:
The safety culture of an interventional laboratory was investigated in terms of the application of the three cardinal principles of radiation protection, namely distance, time and shielding.
Methods:
The application of these principles was observed and recorded with a radiation safety-culture checklist that was compiled by consulting international recommendations. The checklist evaluated the optimal compliance, especially with reference to monitoring of staff exposure, distance from the X-ray source, fluoroscopy techniques pertaining to frame rate, protective devices and personal shielding. The effective radiation dose was measured to the eyes, thyroid, hands and feet of the cardiologist, nurse, floor nurse and radiographer by means of finger dosimeters that were readily available from the local radiation-protection dosimetry service.
Results:
The results, after observing 11 procedures, indicated the absence of table and ceiling-suspended shields, and the distance of the cardiologist's and scrub nurse's feet from the X-ray tube were between 16 and 68 cm, with a mean distance of 59.7 and 58.5 cm, respectively. Most staff (91%) wore the dosimeter inside the lead apron at the collar level without eye protection. The highest dosimeter values recorded were 0.73 mSv to the hand of the cardiologist, 0.45 mSv to the eye of the cardiologist, 0.65 mSv to the hand of the scrub nurse, 0.54 mSv to the eye of the scrub nurse and 0.52 mSv to the foot of the scrub nurse. The dosimeter value to the radiographer's thyroid was 0.42 mSv.
Conclusions:
The dosimeter readings confirmed the highest doses were to the scrub nurse and hand of the interventionalist. The safety culture was non-compliant in terms of staff distance being too close to the X-ray tube, the absence of ceiling and table screens, the theatre door not always being completely closed, and for staff without lead eye glasses, wearing dosimeters outside the lead apron at the collar level.
More Related Videos
10:46Non-fluoroscopic Catheter Tracking for Fluoroscopy Reduction in Interventional Electrophysiology
Published on: May 26, 2015
06:20Irradiator Commissioning and Dosimetry for Assessment of LQ α and β Parameters, Radiation Dosing Schema, and in vivo Dose Deposition
Published on: March 11, 2021
Related Concept Videos
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Imaging Studies for Cardiovascular System V: CT
Cardiac Catheterization I: Pre-Procedure Overview
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Cardiac Catheterization IV: Nursing Management
Healthcare Associated Infections II: Preventive Measures
The best practices for preventing healthcare-associated infections include hand hygiene, patient risk...