Related Experiment Video
Updated: Oct 23, 2025

Effects of Mechanical Methods Used in Peri-implantitis Treatment on Implant Surface Decontamination and Roughness
Published on: March 14, 2025
Failure rates associated with guided versus non-guided dental implant placement: a systematic review and
Nancy Abdelhay1,2, Soni Prasad3, Monica Prasad Gibson4
1Faculty of Medicine and Dentistry, Department of Dentistry, University of Alberta, Edmonton, AB, Canada.
Objective:
The purpose of the systematic review and meta-analysis was to evaluate implant failure rates and their association with guided and free-hand implant placement techniques.
Materials And Methods:
A literature search was conducted across PubMed, Medline via Ovid, Cochrane database, and Google Scholar. The search was completed in September 2020. Series of meta-analyses were conducted to compare implant failure rates with guided and free-hand techniques.
Results:
A total of 3387 articles were identified from the electronic search. After applying the inclusion criteria, eight articles were selected for qualitative assessment and four for quantitative synthesis (meta-analysis). The included studies had a risk ratio of 0.29 (95% CI: 0.15, 0.58), P < 0.001 for the use of guided implant placement. Implant failure rates were affected by the different placement techniques indicated by the test for overall effect (Z = 3.53, P = 0.0004). The incidence of implant failure in guided surgery versus free-hand surgery was found to be 2.25% and 6.42%, respectively.
Conclusion:
Both guided and free-hand implant placement techniques resulted in a high implant survival rate. However, implant failure rates were almost three times higher in the free-hand implant placement category. A guided implant placement approach is recommended for a successful outcome.