Related Experiment Video
Updated: Oct 23, 2025

Tracking the Mammary Architectural Features and Detecting Breast Cancer with Magnetic Resonance Diffusion Tensor Imaging
Published on: December 15, 2014
Magnetic Resonance Imaging for Breast Tumor Bed Delineation: Computed Tomography Comparison and Sequence Variation
Nicola Lowrey1, Christine A Koch1,2, Thomas Purdie1,2
1Radiation Medicine Program, Princess Margaret Cancer Centre, University Health Network, Toronto, Ontario, Canada.
Purpose:
Our purpose was to investigate the interobserver variability in breast tumor bed delineation using magnetic resonance (MR) compared with computed tomography (CT) at baseline and to quantify the change in tumor bed volume between pretreatment and end-of-treatment MR for patients undergoing whole breast radiation therapy.
Methods And Materials:
Forty-eight patients with breast cancer planned for whole breast radiation therapy underwent CT and MR (T1, T1 fat-suppression [T1fs], and T2) simulation in the supine treatment position before radiation therapy and MR (T1, T1fs, and T2) at the end of treatment in the same position. Two observers delineated 50 tumor beds on the CT and all MR sequences and assigned cavity visualization scores to the images. The primary endpoint was interobserver variability, measured using the conformity index (CI).
Results:
The mean cavity visualization scores at baseline were 3.14 (CT), 3.26 (T1), 3.41 (T1fs), and 3.58 (T2). The mean CIs were 0.65, 0.65, 0.72, and 0.68, respectively. T1fs significantly improved interobserver variability compared with CT, T1, or T2 (P < .001, P < .001, and P = .011, respectively). The CI for T1fs was significantly higher than T1 and T2 at the end of treatment (mean 0.72, 0.64, and 0.66, respectively; P < .001). The mean tumor bed volume on the T1fs sequence decreased from 18 cm3 at baseline to 13 cm3 at the end of treatment (P < .01).
Conclusions:
T1fs reduced interobserver variability on both pre- and end-of-treatment scans and measured a reduction in tumor bed volume during whole breast radiation therapy. This rapid sequence could be easily used for adaptive boost or partial breast irradiation, especially on MR linear accelerators.
More Related Videos
12:23Multi-modal Imaging of Angiogenesis in a Nude Rat Model of Breast Cancer Bone Metastasis Using Magnetic Resonance Imaging, Volumetric Computed Tomography and Ultrasound
Published on: August 14, 2012
05:19Magnetic Resonance Imaging Assessment of Carcinogen-induced Murine Bladder Tumors
Published on: March 29, 2019
Related Concept Videos
Magnetic Resonance Imaging
Imaging Studies IV: Magnetic Resonance Imaging
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...