Related Experiment Video
Updated: Oct 23, 2025

Expired CO2 Measurement in Intubated or Spontaneously Breathing Patients from the Emergency Department
Published on: January 29, 2011
End-tidal carbon dioxide measurements as a surrogate to arterial carbon dioxide during pediatric laparoscopic
Hala Saad Abdel-Ghaffar1, Mohammed Abdel-Moneim Bakr1, Mohamed Abdel-Kadr Osman2
1Assiut University, Faculty of Medicine, Anesthesia and Intensive Care Department, Assiut, Egypt.
Background:
Maintaining normocapnia during mechanical ventilation in anesthetized children during laparoscopic surgeries is highly recommended. There is a debate regarding the use of capnography (ETCO2) as a trend monitor for evaluation of arterial carbon dioxide levels (PaCO2). We analyzed the relationship between ETCO2 and PaCO2 with time in elective pediatric laparoscopic surgeries.
Methods:
This study was a prospective observational cohort analysis of 116 paired comparisons between PaCO2 and ETCO2 computed from 29 children (ASA I, 12...72 months). Arterial blood samples were withdrawn before, at 15...minutes and 30...minutes during pneumoperitoneum and 1...minute after deflation. ETCO2 value was recorded simultaneously, while arterial blood was withdrawn. PaCO2...ETCO2 relationship was evaluated by Pearson's correlation coefficients and Bland Altman Method of agreement.
Results:
Out of the 116 comparisons analyzed, a PaCO2...ETCO2 difference beyond 0 to ..± 5...mmHg was recorded in 71 comparisons (61.2%) with negative difference in 34 comparisons (29.3%). A positive significant correlation between PaCO2 and ETCO2 was recorded before (r...=...0.617, p...=...0.000) and at 15...minutes (r...=...0.582, p...=...0.001), with no significant correlation at 30 minutes (r...=...0.142, p...=...0.461), either after deflation (r...=...0.108, p...=...0.577). Bland-Altman plots showed agreement between ETCO2 and PaCO2 before inflation with mean PaCO2-ETCO2 difference 0.14........5.6...mmHg (limits of 95% agreement -10.84...11.2, simple linear regression testing p-value 0.971), with no agreement at 15...minutes (0.51........7.15, -13.5...14.5, p...=...0.000), 30...minutes. (2.62........7.83, -12.73...17.97, p...=...0.000), or after deflation (1.81........6.56, -10.93...14.55, p...=...0.015).
Conclusion:
Usage of capnography as a trend monitor in pediatric laparoscopic surgeries may not be a reliable surrogate for PaCO2 levels.
Trial Registration:
Clinical Trials. gov (Identifier: NCT03361657).
More Related Videos
07:51Evaluation of Capnography Sampling Line Compatibility and Accuracy when Used with a Portable Capnography Monitor
Published on: September 29, 2020
08:25Combining Volumetric Capnography And Barometric Plethysmography To Measure The Lung Structure-function Relationship
Published on: January 8, 2019
Related Concept Videos
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...
Endoscopic Procedures IV: Sigmoidoscopy and Laproscopy
Sigmoidoscopy
Sigmoidoscopy is a diagnostic procedure that uses a flexible sigmoidoscope equipped with a light source and camera to examine the rectum and sigmoid colon. The procedure involves inserting the tube through the anus...
Endoscopic Studies II: Thoracocentesis
Description
Excess pleural fluid or air may accumulate in some respiratory disorders in the thoracic cavity. To treat pleural effusion, a physician conducts thoracentesis by carefully piercing the chest wall and entering...