Generating pseudo-computerized tomography (P-CT) scan images from magnetic resonance imaging (MRI) images using
Niloofar Yousefi Moteghaed1, Ahmad Mostaar1, Payam Azadeh2
1Department of Medical Physics and Biomedical Engineering, School of Medicine, Shahid Beheshti University of Medical Sciences, Tehran, Iran.
Purpose:
The substitution of computerized tomography (CT) with magnetic resonance imaging (MRI) has been investigated for external radiotherapy treatment planning. The present study aims to use pseudo-CT (P-CT) images created by MRI images to calculate the dose distribution for facilitating the treatment planning process.
Methods:
In this work, following image segmentation with a fuzzy clustering algorithm, an adaptive neuro-fuzzy algorithm was utilized to design the Hounsfield unit (HU) conversion model based on the features vector of MRI images. The model was generated on the set of extracted features from the gray-level co-occurrence matrices and the gray-level run-length matrices for 14 arbitrarily selected patients with brain malady. The performance of the algorithm was investigated on blind datasets through dose-volume histogram and isodose curve evaluations, using the RayPlan treatment planning system (TPS), along with the gamma analysis and statistical indices.
Results:
In the proposed approach, the mean absolute error within the range of 45.4 HU was found among the test data. Also, the relative dose difference between the planning target volume region of the CT and the P-CT was 0.5%, and the best gamma pass rate for 3%/3 mm was 97.2%.
Conclusion:
The proposed method provides a satisfactory average error rate for the generation of P-CT data in the different parts of the brain region from a collection of MRI series. Also, dosimetric parameters evaluation shows good agreement between reference CT and related P-CT images.
More Related Videos
04:09Predicting Treatment Response to Image-Guided Therapies Using Machine Learning: An Example for Trans-Arterial Treatment of Hepatocellular Carcinoma
Published on: October 10, 2018
10:48PET and MRI Guided Irradiation of a Glioblastoma Rat Model Using a Micro-irradiator
Published on: December 28, 2017
Related Concept Videos
Magnetic Resonance Imaging
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Brain Imaging
These technologies include computerized axial tomography (CAT or CT scans), positron-emission tomography (PET scans), magnetic resonance imaging (MRI), functional magnetic resonance imaging (fMRI), and Transcranial Magnetic...