Related Experiment Video
Updated: Oct 23, 2025

A Whole Body Dosimetry Protocol for Peptide-Receptor Radionuclide Therapy PRRT: 2D Planar Image and Hybrid 2D+3D SPECT/CT Image Methods
Published on: April 24, 2020
Does the Incremental Value of 123I-Metaiodobenzylguanidine SPECT/CT over Planar Imaging Justify the Increase in
Dorra Ben-Sellem1, Naima Ben-Rejeb2
1Université de Tunis El Manar, Faculté de Médecine de Tunis, Laboratoire de Recherche en Biophysique Et Technologies Médicales (LRBTM) ISTMT, Institut Salah AZAIEZ: Service de Médecine Nucléaire, 1006 Tunis, Tunisia.
Purpose:
Planar scintigraphy with 123I-radiolabeled metaiodobenzylguanidine (123I-mIBG) is an important imaging modality to evaluate neuroblastoma. In recent years, Single Photon Emission Computed Tomography combined with Computed Tomography (SPECT/CT) has revolutionized nuclear medicine. Nevertheless, the addition of the CT has increased the patients' irradiation. We aimed to evaluate the incremental benefits of 123I-mIBG SPECT/CT over conventional planar imaging and to estimate the relative increase of radiation dose.
Methods:
We retrospectively evaluated the added value of 56 SPECT/CT performed in 40 children in terms of better characterization of the lesion and its locoregional extension, better lymph node staging, detection of new lesions, and elimination of false positives by a paired comparison between the planar images and the SPECT/CT ones. Then, we calculated the percentage contribution of the additional radiation of the CT in this hybrid imagery.
Results:
In 88% (49 out of 56) of the examinations, SPECT/CT provided additional information, which was crucial in 20% of the cases. It allowed a better characterization of the lesion and its locoregional extension in 44 cases, a better lymph node staging in 28 cases, the detection of 33 new lesions, and the elimination of 9 false positives. The CT effective dose was significantly lower than the SPECT one. The average additional radiation exposure due to CT was 12% (4-23%).
Conclusion:
123I-mIBG SPECT/CT has an undeniable added value that improves planar imaging interpretation and impacts patient management. These potential benefits would justify the low additional radiation induced by the CT.
More Related Videos
10:48PET and MRI Guided Irradiation of a Glioblastoma Rat Model Using a Micro-irradiator
Published on: December 28, 2017
07:57Positron Emission Tomography-based Dose Painting Radiation Therapy in a Glioblastoma Rat Model using the Small Animal Radiation Research Platform
Published on: March 24, 2022
Related Concept Videos
Radiological Investigation I: X-ray and CT
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Imaging Studies III: Computed Tomography
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies for Cardiovascular System V: CT