Related Experiment Video
Updated: Oct 23, 2025

Tracking the Mammary Architectural Features and Detecting Breast Cancer with Magnetic Resonance Diffusion Tensor Imaging
Published on: December 15, 2014
Dual-energy CT in differentiating benign sinonasal lesions from malignant ones: comparison with simulated
Peng Wang1,2, Zuohua Tang3, Zebin Xiao1,4
1Department of Radiology, Eye & ENT Hospital of Shanghai Medical School, Fudan University, 83 Fenyang Road, Shanghai, 200031, People's Republic of China.
Objectives:
To explore the value of dual-energy CT (DECT) for differentiating benign sinonasal lesions from malignant ones, and to compare this finding with simulated single-energy CT (SECT), conventional MRI (cMRI), and diffusion-weighted imaging (DWI).
Methods:
Patients with sinonasal lesions (38 benign and 34 malignant) who were confirmed by histopathology underwent DECT, cMRI, and DWI. DECT-derived parameters (iodine concentration (IC), effective atomic number (Eff-Z), 40-180 keV (20-keV interval), virtual non-enhancement (VNC), slope (k), and linear-mixed 0.3 (Mix-0.3)), DECT morphological features, cMRI characteristics, and ADC value of benign and malignant tumors were compared using t test or chi-square test. Receiver operating characteristic (ROC) curve was performed to evaluate the diagnostic performance, and the area under the ROC curve (AUC) was compared using the Z test to select the optimal diagnostic approach.
Results:
Significantly higher DECT-derived single parameters (IC, Eff-Z, 40 keV, 60 keV, 80 keV, slope (k), Mix-0.3) were found in malignant lesions than those of benign sinonasal lesions (all p < 0.004, Bonferroni correction). Combined quantitative parameters (IC, Eff-Z, 40 keV, 60 keV, 80 keV, slope (k)) can improve the diagnostic efficiency for discriminating these two entities. Combination of DECT quantitative parameters and morphological features can further improve the overall diagnostic performance, with AUC, sensitivity, specificity, and accuracy of 0.935, 96.67%, 90.00%, and 93.52%. Moreover, the AUC of DECT was higher than those of Mix-0.3 (simulated SECT), cMRI, DWI, and cMRI+DWI.
Conclusions:
Compared with simulated SECT, cMRI, and DWI, DECT appears to be a more accurate imaging technique for differentiating benign from malignant sinonasal lesions.
Key Points:
• DE can differentiate benign sinonasal lesions from malignant ones based on DECT-derived qualitative parameters. • DECT appears to be more accurate in the diagnosis of sinonasal lesions when compared with simulated SECT, cMRI, and DWI.
More Related Videos
Related Concept Videos
Magnetic Resonance Imaging
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...

