Related Experiment Video
Updated: Oct 23, 2025

Non-fluoroscopic Catheter Tracking for Fluoroscopy Reduction in Interventional Electrophysiology
Published on: May 26, 2015
Zero fluoroscopy approach versus fluoroscopy approach for cardiac arrhythmia ablations: A systematic review and
Chanavuth Kanitsoraphan1, Chol Techorueangwiwat1, Pattara Rattanawong2
1Internal Medicine Residency Program, University of Hawaii John A Burns School of Medicine, Honolulu, Hawaii, USA.
Background:
Radiofrequency catheter ablation for cardiac arrhythmias has traditionally been guided by fluoroscopy. Fluoroscopy exposes the patient, operator, and staff to ionizing radiation which has no safe dose void of stochastic and deterministic biologic risks. Zero fluoroscopy (ZF) approaches for catheter ablation have been advocated to eliminate these risks. We conducted a meta-analysis comparing acute procedure success, recurrence-free survival, complications, and procedure times between the approaches.
Methods:
We conducted a literature search from inception through December 2020 in the databases of EMBASE and MEDLINE. We included randomized controlled trials and cohorts that compared the outcomes of interest in ZF and conventional/low fluoroscopy (CF/LF) approaches. The outcomes sought were acute procedure success, recurrence-free survival, complications, and procedure times. Effect estimates were combined, using the random-effects, generic inverse variance method of DerSimonian and Laird.
Results:
Sixteen studies from 2013 to 2020, including 6052 patients (2219 ZF, 3833 CF/LF) were included. There were no significant differences in acute procedure success rate (odds ratio [OR]: 1.10, 95% confidence interval [CI]: 0.75-1.59), recurrence-free survival (OR: 1.08, 95% CI: 0.78-1.49), periprocedural complication rate (OR: 0.72, 95% CI: 0.45-1.16), or total procedure time (weighted mean difference 2.32 min, 95% CI: -2.85-7.50) between ZF and CF/LF approaches, respectively. Overall, only 1.26% of patients crossed over from ZF to CF/LF arm.
Conclusions:
Periprocedural and postprocedural outcomes with a ZF approach compared favorably with traditional fluoroscopic guidance without increasing procedural times. As comfort with ZF grows, coupled with evolving mapping technologies, this method has potential to become the standard approach for catheter ablation.
Related Concept Videos
Dysrhythmias VI: Management of Dysrhythmias
Dysrhythmias V: Evaluating Dysrhythmias
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Disturbances in Heart Rhythm
Arrhythmias are categorized by their speed, rhythm, and origin. A slow heart...
Mechanism of Cardiac Arrhythmias

