Related Experiment Video
Updated: Oct 23, 2025

Automated Midline Shift and Intracranial Pressure Estimation based on Brain CT Images
Published on: April 13, 2013
Aneurysm morphological prediction of intracranial aneurysm rupture in elderly patients using four-dimensional CT
Yudi Cui1, Haixia Xing2, Jiafeng Zhou3
1Department of Neurosurgery, Renji Hospital Shanghai Jiaotong University School of Medicine, Shanghai 200127, China.
Objective:
The natural history of unruptured intracranial aneurysms (UIAs) in elderly patients remains poorly understood, and the treatment of UIAs is controversial. The presence of irregular pulsation detected by four-dimensional CT angiography (4D-CTA) is associated with ruptured aneurysms. We aimed to investigate the morphological predictors of irregular pulsation of aneurysms in elderly patients.
Patients And Methods:
We performed a prospective study of intracranial aneurysms detected by 4D-CTA. Elderly patients were defined as those more than 60 years of age. The irregular pulsation was defined as a focal protuberance during a cardiac cycle. We performed multivariate analyses to determine the associations of clinical characteristics and aneurysm morphologies with the irregular pulsation of aneurysms.
Results:
A total of 128 elderly patients with 166 intracranial aneurysms was included. The irregular pulsation occurred in 71 (42.8%) aneurysms. The multivariate analysis showed that a large size ratio (p = 0.006), posterior circulation aneurysms (p = 0.033), the presence of a daughter dome (p = 0.006), and aneurysm rupture (p = 0.032) were independently associated with the irregular pulsation. The multivariate analysis of predictors of irregular pulsation of unruptured aneurysms showed that size ratio (p = 0.01) and the presence of a daughter dome (p = 0.016) were independent predictors of irregular pulsation.
Conclusion:
A large size ratio, posterior circulation aneurysms, the presence of a daughter dome, and aneurysm rupture were independent predictors of the irregular pulsation of aneurysms in elderly patients. The morphological characteristics detected by 4D-CTA may be helpful to evaluate the risk of rupture of aneurysms.
More Related Videos
09:32Time-Resolved, Dynamic Computed Tomography Angiography for Characterization of Aortic Endoleaks and Treatment Guidance via 2D-3D Fusion-Imaging
Published on: December 9, 2021
09:32Manufacturing Abdominal Aorta Hydrogel Tissue-Mimicking Phantoms for Ultrasound Elastography Validation
Published on: September 19, 2018
Related Concept Videos
Aneurysm III: Interprofessional Care
Aneurysm II: Clinical Manifestations and Diagnostic Studies