Related Experiment Video
Updated: Oct 23, 2025

Direct Pressure Monitoring Accurately Predicts Pulmonary Vein Occlusion During Cryoballoon Ablation
Published on: February 26, 2013
Hemodynamic intolerance and pericardial effusion associated with high-frequency jet ventilation during pulmonary vein
Patricia Tung1, Jonathan W Waks1, Sankalp Sehgal2
1Division of Cardiovascular Medicine, Harvard-Thorndike Arrhythmia Institute, Beth Israel Deaconess Medical Center, Boston, Massachusetts.
Background:
High-frequency jet ventilation (HFJV) is used during pulmonary vein isolation (PVI) to increase catheter stability and improve outcomes. In prior studies, hemodynamic intolerance to HFJV was rare.
Objectives:
To evaluate the incidence of hemodynamic or respiratory intolerance of HFJV during PVI.
Methods:
Retrospective observational analysis of consecutive patients undergoing PVI performed by 2 operators (PT, JW) at our institution between February 2019 and June 2020 who developed persistent hypotension or abnormal ventilatory parameters in association with HFJV.
Results:
Among 194 PVIs, there were 8 cases (4%) of conversion from HFJV to conventional ventilation, 6 for refractory hypotension and 2 for persistently abnormal gas exchange. In 6 patients, including 5 of the 6 patients with refractory hypotension, a new, small pericardial effusion without tamponade was noted just after HFJV was initiated. In patients with persistent hypotension, a decrease in left ventricular filling and systolic function was frequently noted. Both the hemodynamic changes and effusion resolved almost immediately after discontinuation of HFJV. In 4 patients rechallenged with HFJV, the hypotension and/or effusion recurred quickly and again resolved immediately after return to conventional ventilation.
Conclusion:
HFJV-associated hypotension and systolic dysfunction, often accompanied by a transient pericardial effusion, is present in a small proportion of patients undergoing PVI, and resolves with cessation of HFJV. The mechanism of these changes is unclear and warrants further study.
More Related Videos
Related Concept Videos
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation...
Pulmonary Embolism I: Introduction
Mechanical Ventilation I: Indication and Settings
Measurement of Blood Pressure
Pulmonary Embolism II: Diagnostic Studies and Interprofessional Care