Related Experiment Video
Updated: Oct 23, 2025

Intra-Operative Neural Monitoring of Thyroid Surgery in a Porcine Model
Published on: February 11, 2019
Comparative Effectiveness of Recurrent Laryngeal Nerve Monitoring Techniques in Pediatric Surgery
Claire M Lawlor1, Jay Meisner2, Russell W Jennings2
1Department of Otolaryngology, Children's National Health System, Washington, District of Columbia, USA.
Objectives/Hypothesis:
The recurrent laryngeal nerve (RLN) is at risk during pediatric cervical, thoracic, and cardiac surgery. We aim to determine the feasibility and effectiveness of RLN monitoring techniques in all pediatric patients.
Study Design:
Retrospective case series.
Methods:
Retrospective review of patients/procedures with RLN(s) at risk and RLN monitoring at Boston Children's Hospital July 2019-October 2020.
Primary Outcomes:
pre/postoperative vocal fold mobility by awake flexible fiberoptic laryngoscopy (FFL).
Results:
One hundred one patients (median [interquartile range, IQR] age 14.6 months [4.6-49.7 months], weight 10 kg [5.2-16.2 kg]) underwent 122 procedures with RLN(s) at risk. RLN monitoring attempted 111 cases, successful 96 (84%). Surgical indications: esophageal atresia/tracheoesophageal fistula, and tracheobronchomalacia. Sixty-two (56%) procedures in reoperative field. Median follow-up 112 days (IQR 41-230). Pre/postoperative FFL performed 84 procedures (69%), 19 new postoperative RLN injuries (16%), median age 12 months, reoperative fields 11 (18%). Prass probes: 34 cases (28 successful, 82%), 6 injuries (18%), age 12.2 (5.8-23.6) months. Dragonfly electrodes: 45 cases (37 successful, 82%), 8 injuries (18%), age 7.5 (3.8-19) months. Nerve integrity monitoring (NIM) integrated electrode endotracheal tube: 33 cases (33 successful, 100%), 5 injuries (15%), age 90 (58.8-136.7) months. Automatic periodic stimulation (APS): 16 cases, 13 successful (81%), four injuries (25%), age 7.2 (5.3-20.6) months. NIM RLN monitoring is significantly more successful than Prass, Dragonfly (95%CI -0.3 to 0.02, P = .02; and 95%CI 0.05-0.31, P = .008). Rates of injury are not different between types of RLN monitoring (P = .94), with APS use (P = .47), or with monitoring success (95%CI -0.36 to 0.09, P = .28).
Conclusions:
RLN monitoring is feasible in pediatric patients of all ages. Although NIM type RLN monitoring success is superior, all forms offer similar rates of nerve protection.
Level Of Evidence:
3 Laryngoscope, 132:889-894, 2022.
More Related Videos
07:22Minimally Invasive Murine Laryngoscopy for Close-Up Imaging of Laryngeal Motion During Breathing and Swallowing
Published on: December 1, 2023
11:46Investigation of the Electrophysiological and Thermographic Safety Parameters of Surgical Energy Devices During Thyroid and Parathyroid Surgery in a Porcine Model
Published on: October 13, 2022