Single volar locking plating for the intra- and extra-articular distal radius fractures with dorsal metaphyseal
Xue-Yang Gui1, Zhao-Hui Cheng2, Hong-Fei Shi3
1Department of Orthopedics, Nanjing Drum Tower Hospital, The Affiliated Hospital of Nanjing University Medical School, No. 321 Zhongshan Road, Nanjing, China.
Background:
Volar locking plating remains a popular method for the surgical management of distal radius fractures. Dorsal metaphyseal comminution (DMC) is a common fracture pattern which weakens the stability during fracture fixation. In this study, we aimed to compare the radiographic and functional outcome of the intra- and extra-articular distal radius fractures with DMC following single volar locking plate fixation.
Materials And Methods:
Patients suffered from a distal radius fracture with DMC were reviewed in the clinical database of the authors' institution between Jan 2016 and Jan 2020. The included patients were classified into the extra-articular (A3) group or the intra-articular (C2 and C3) group according to the AO/OTA system. The radiological parameters, wrist range of motion, and functional outcomes were evaluated following open reduction and volar locking plate fixation.
Results:
A total of 130 patients were included in this study with a mean follow-up length of 17.2 months. Compared with the A3 fracture group, no significant fracture re-displacement or reduced wrist ROMs was observed in the C2 fractures after 12-month's follow-up. However, significantly decreased volar tilt (P = 0.003) as well as the extension/flexion ROMs were observed in the C3 fractures comparing to the A3 fractures. Most of the patients achieved an excellent (n = 75) or good (n = 51) Gartland and Werley wrist score. Four patients with C3 fractures resulted in a fair functional outcome due to a significant loss of volar tilt during follow-up.
Conclusions:
The single volar locking plate fixation provided sufficient stability for distal radius fractures with DMC, and resulted in similar radiological and functional outcomes in the intra-articular distal radius fractures with a simple articular component (C2 fractures) as those in the extra-articular fractures. Considering the intra-articular fractures with multifragmentary articular component (C3 fracture), despite of the subsequent loss of volar tilt, the majority of the patients achieved good to excellent wrist function following single volar locking plating.
Trial Registration:
This study has been registered on the ClinicalTrials.gov.
More Related Videos
04:41Treatment with Locking Intramedullary Nailing for Intertrochanteric Fracture of the Femur Utilizing a New Awl with a Distal Positioner
Published on: June 6, 2025
04:19Minimally Invasive Treatment for Thoracolumbar Burst Fracture Using Sagittal Alignment Screws and A Trauma Reduction Device
Published on: November 8, 2024
Related Concept Videos
Fractures: Bone Repair
Minor fractures with no bone displacement are treated by immobilizing the fractured bone using a cast or splint. However, in the case of fractures with displaced bones, the broken bones are repositioned before immobilization to ensure successful healing without deformation and loss of function. The realignment of fractured bone ends is performed through a process called reduction. If the...
Bones of the Upper Limb: Radius
The radius has a nail-shaped head, and a...
