Lung diffusing capacity for nitric oxide measured by two commercial devices: a randomised crossover comparison in
Thomas Radtke1,2, Quintin de Groot1,3,2, Sarah R Haile4
1Division of Occupational and Environmental Medicine, Epidemiology, Biostatistics and Prevention Institute, University of Zurich & University Hospital Zurich, Zurich, Switzerland.
Abstract:
In Europe, two commercial devices are available to measure combined single-breath diffusing capacity of the lung for nitric oxide (D LNO) and carbon monoxide (D LCO) in one manoeuvre. Reference values were derived by pooling datasets from both devices, but agreement between devices has not been established. We conducted a randomised crossover trial in 35 healthy adults (age 40.0±15.5 years, 51% female) to compare D LNO (primary end-point) between MasterScreen™ (Vyaire Medical, Mettawa, IL, USA) and HypAir (Medisoft, Dinant, Belgium) devices during a single visit under controlled conditions. Linear mixed models were used adjusting for device and period as fixed effects and random intercept for each participant. Difference in D LNO between HypAir and MasterScreen was 24.0 mL·min-1·mmHg-1 (95% CI 21.7-26.3). There was no difference in D LCO (-0.03 mL·min-1·mmHg-1, 95% CI -0.57-0.12) between devices while alveolar volume (V A) was higher on HypAir compared to MasterScreen™ (0.48 L, 95% CI 0.45-0.52). Disparity in the estimation of V A and the rate of NO uptake (KNO=D LNO/V A) could explain the discrepancy in D LNO between devices. Disparity in the estimation of V A and the rate of CO uptake (KCO=D LCO/V A) per unit of V A offset each other resulting in negligible discrepancy in D LCO between devices. Differences in methods of expiratory gas sampling and sensor specifications between devices likely explain these observations. These findings have important implications for derivation of D LNO reference values and comparison of results across studies. Until this issue is resolved, reference values, established on the respective devices, should be used for test interpretation.
Related Concept Videos
Pulmonary Function Tests
Pulmonary Function Tests are crucial diagnostic tools for assessing respiratory function, particularly in patients with chronic respiratory disorders. They comprehensively evaluate lung volumes, ventilatory function, breathing mechanics, diffusion, and gas exchange. These tests help diagnose pulmonary diseases and play a significant role in monitoring disease progression, evaluating disability, and assessing response to therapy.
PFTs involve using a spirometer, a...
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...
Lung Capacity
Respiratory Capacities
One key metric is the Inspiratory Capacity (IC), which represents the maximum amount of air that can be inhaled with full effort. IC is calculated by summing the tidal volume and inspiratory reserve volume, typically ranging from 2.4 to 3.6 liters.
The Functional Residual Capacity (FRC) represents the air in the...
Respiratory Volumes and Capacities