Related Experiment Video
Updated: Oct 22, 2025

Direct and Indirect Culture Methods for Studying Biodegradable Implant Materials In Vitro
Published on: April 15, 2022
Disinfection of Impression Materials with Glutaraldehyde, Ultraviolet Radiation, and Autoclave: A Comparative Study
Monica Kotwal1, Vishal Partap Singh2, Humaira Mushtaq2
1Department of Prosthodontics, Indira Gandhi Government Dental College, Jammu, Jammu and Kashmir, India.
Background:
The present study was conducted to compare various methods of disinfection of impression materials such as glutaraldehyde, ultraviolet (UV) radiation, and autoclave.
Materials And Methods:
The present study was conducted on eighty alginate impression materials which were disinfectant with 2.2% glutaraldehyde, UV radiation, and autoclave. The pre- and postbacterial count was assessed.
Results:
The mean premicrobial contamination in Group I was 362.2 106 colony-forming unit (CFU)/ml, in Group II was 306.4 106 CFU/ml, and in Group III was 336.2 106 CFU/ml. The mean postmicrobial contamination in Group I was 65.2 106 CFU/ml, in Group II was 76.7 106 CFU/ml, and in Group III was 28.4 106 CFU/ml.
Conclusion:
The authors found that autoclave proved to be better in terms of reduction in bacterial colonies as compared to glutaraldehyde and UV radiation.
More Related Videos
Related Concept Videos
Methods of Sterilization I: Physical Methods
Steam sterilization uses non-toxic, low-cost moist heat in the form of saturated steam under pressure, which is fast, microbicidal, and sporicidal, and quickly warms and penetrates fabrics. Autoclaves, or steam sterilizers, expose each item to direct steam contact for a predetermined time at the necessary...
Methods of Sterilization II: Chemical Methods
Using chemical sterilization rather than heat to clean out equipment is recommended. It eradicates and removes all bacteria,...
Cleaning, Sterilization, and Disinfection
Cleaning
The cleaning process usually involves using water with detergents or enzymatic cleaner and removing foreign material from objects and surfaces, including organic material such as body fluids or inorganic material like soil. Cleaning is performed before high-level disinfection and sterilization because foreign materials on the cover of the devices interfere with process...
Physical Methods for Controlling Microbial Growth: Radiation and Filtration
Chemical Agents for Microbial Control
Physical Methods for Controlling Microbial Growth: Temperature