In Vitro Evaluation of The Effects Of Er,Cr:YSGG and Diode Lasers Used on Titanium Cylinder
Published on: June 6, 2025
Assessment of Titanium Level in Submucosal Plaque Around Healthy Implants and Implants with Peri-implantitis: A
Juzer Rasul1, Manoj Kumar Thakur2, Barkha Maheshwari3
1Reader and HOD of Public Health Dentistry, Swargiya Dadasaheb Kalmegh Smruti Dental College and Hospital, Nagpur, Maharashtra, India.
Background:
The present study focused on assessing the level of titanium in submucosal plaque in the peri-implant area with peri-implantitis in comparison to healthy implants.
Methodology:
Sixty patients with titanium dental implants were recruited. The degree of titanium in submucosal plaque around peri-implantitis and healthy implants was estimated using inductively coupled plasma mass spectrometry.
Results:
The mean ± standard deviation probing depth in Group I was 3.12 ± 1.1 and in Group II was 7.2 ± 2.5; gingival index was 0.64 ± 0.3 and 1.64 ± 0.8 in Group I and Group II, respectively. The plaque index was 0.82 ± 0.2 in Group I and 1.5 ± 0.6 in Group II. The mean plaque mass in Group I was 24.1 ± 3.8 ng/ul and 49.3 ± 6.4 ng/ul in Group II. The mean titanium level in Group I was 0.08 ± 0.02 μg and in Group II was 0.91 ± 0.04 μg. A highly significant difference between both groups was found (P < 0.05).
Conclusion:
There was a significantly higher titanium level in submucosal plaque around dental implants with signs of peri-implantitis as compared to healthy dental implants.