Simultaneous Multi-Heartbeat ECGI Solution with a Time-Varying Forward Model: a Joint Inverse Formulation
Jake A Bergquist1, Jaume Coll-Font2, Brian Zenger1
1Biomedical Engineering Department, University of Utah, SLC, UT, 84112, USA.
Abstract:
Electrocardiographic imaging (ECGI) is an effective tool for noninvasive diagnosis of a range of cardiac dysfunctions. ECGI leverages a model of how cardiac bioelectric sources appear on the torso surface (the forward problem) and uses recorded body surface potential signals to reconstruct the bioelectric source (the inverse problem). Solutions to the inverse problem are sensitive to noise and variations in the body surface potential (BSP) recordings such as those caused by changes or errors in cardiac position. Techniques such as signal averaging seek to improve ECGI solutions by incorporating BSP signals from multiple heartbeats into an averaged BSP with a higher SNR to use when estimating the cardiac bioelectric source. However, signal averaging is limited when it comes to addressing sources of BSP variability such as beat to beat differences in the forward solution. We present a novel joint inverse formulation to solve for the cardiac source given multiple BSP recordings and known changes in the forward solution, here changes in the heart position. We report improved ECGI accuracy over signal averaging and averaged individual inverse solutions using this joint inverse formulation across multiple activation sequence types and regularization techniques with measured canine data and simulated heart motion. Our joint inverse formulation builds upon established techniques and consequently can easily be applied with many existing regularization techniques, source models, and forward problem formulations.
Related Concept Videos
Correlation between ECG and Cardiac Cycle
A cardiac action potential originates in the SA node and spreads throughout the atria and the AV node in approximately 0.03 seconds. This results in the P wave in an ECG and triggers atrial contraction. The action potential is then briefly slowed at the AV node, allowing the atria to contract and fill the ventricles with blood before...
Multi-input and Multi-variable systems
In the absence...
Multicompartment Models: Overview
These models offer a more comprehensive representation of drug behavior in the body than one-compartment models. They accommodate the complexity of drug distribution,...
Cardiac Output I:Effect of Heart Rate on Cardiac Output
Cardiac output (CO) refers to the total amount of blood ejected by one of the ventricles in liters per minute (L/min). In a resting adult, CO ranges from 5 to 6 L/min, adjusting according to the body's metabolic requirements.
Effect of Heart Rate on Cardiac Output
Cardiac output adapts to metabolic demands during stress, physical activity, or illness. The autonomic nervous system regulates heart rate via the sinoatrial node. The parasympathetic nervous system decreases heart...
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Imaging Studies for Cardiovascular System I:Echocardiography
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion,...