Related Experiment Video
Updated: Oct 22, 2025

Retrospective Cardiac Gating with A Prototype Small-Animal X-ray Computed Tomograph
Published on: February 21, 2025
CycleGAN denoising of extreme low-dose cardiac CT using wavelet-assisted noise disentanglement
Jawook Gu1, Tae Seong Yang2, Jong Chul Ye1
1Bio Imaging, Signal Processing and Learning Laboratory, Department of Bio and Brain Engineering, KAIST, 291, Daehak-ro, Yuseong-gu, Daejeon, 34141, Republic of Korea.
Abstract:
In electrocardiography (ECG) gated cardiac CT angiography (CCTA), multiple images covering the entire cardiac cycle are taken continuously, so reduction of the accumulated radiation dose could be an important issue for patient safety. Although ECG-gated dose modulation (so-called ECG pulsing) is used to acquire many phases of CT images at a low dose, the reduction of the radiation dose introduces noise into the image reconstruction. To address this, we developed a high performance unsupervised deep learning method using noise disentanglement that can effectively learn the noise patterns even from extreme low dose CT images. For noise disentanglement, we use a wavelet transform to extract the high-frequency signals that contain the most noise. Since matched low-dose and high-dose cardiac CT data are impossible to obtain in practice, our neural network was trained in an unsupervised manner using cycleGAN for the extracted high frequency signals from the low-dose and unpaired high-dose CT images. Once the network is trained, denoised images are obtained by subtracting the estimated noise components from the input images. Image quality evaluation of the denoised images from only 4% dose CT images was performed by experienced radiologists for several anatomical structures. Visual grading analysis was conducted according to the sharpness level, noise level, and structural visibility. Also, the signal-to-noise ratio was calculated. The evaluation results showed that the quality of the images produced by the proposed method is much improved compared to low-dose CT images and to the baseline cycleGAN results. The proposed noise-disentangled cycleGAN with wavelet transform effectively removed noise from extreme low-dose CT images compared to the existing baseline algorithms. It can be an important denoising platform for low-dose CT.
Related Concept Videos
Imaging Studies for Cardiovascular System V: CT
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
¹³C NMR: ¹H–¹³C Decoupling
A broadband decoupling technique is used to simplify these complex, sometimes overlapping, signals. Broadband decoupling relies on a...