In Situ Surface Temperature Measurement in a Conveyor Belt Furnace via Inline Infrared Thermography
Published on: May 30, 2020
Detection of Defects in Geomembranes Using Quasi-Active Infrared Thermography
Yue Ma1, Francis Rose2, Leslie Wong1
1Department of Mechanical and Aerospace Engineering, Monash University, Wellington Rd, Clayton, VIC 3800, Australia.
Abstract:
High-density polyethylene geomembranes are employed as covers for the sewage treatment lagoons at Melbourne Water Corporation's Western Treatment Plant, to harvest the biogas produced during anaerobic degradation, which is then used to generate electricity. Due to its size, inspecting the cover for defects, particularly subsurface defects, can be challenging, as well as the potential for the underside of the membrane to come into contact with different substrates, viz. liquid sewage, scum (consolidated solid matter), and biogas. This paper presents the application of a novel quasi-active thermography inspection method for subsurface defect detection in the geomembrane. The proposed approach utilises ambient sunlight as the input thermal energy and cloud shading as the trigger for thermal transients. Outdoor laboratory-scale experiments were conducted to study the proposed inspection technique. A pyranometer was used to measure the intensity of solar radiation, and an infrared thermal camera was used to measure the surface temperature of the geomembrane. The measured temperature profile was analysed using three different algorithms for thermal transient analysis, based on (i) the cooling constant from Newton's law of cooling, (ii) the peak value of the logarithmic second derivative, and (iii) a frame subtraction method. The outcomes from each algorithm were examined and compared. The results show that, while each algorithm has some limitations, when used in combination the three algorithms could be used to distinguish between different substrates and to determine the presence of subsurface defects.