Related Experiment Video
Updated: Oct 22, 2025

Quantifying the Relative Thickness of Conductive Ferromagnetic Materials Using Detector Coil-Based Pulsed Eddy Current Sensors
Published on: January 16, 2020
Robust Estimation of Contact Force and Location for Magnetic-Field-Based Soft Tactile Sensor Considering Magnetic
Xiaofeng Yang1, Bingchu Li1, Lihong Yang1
1School of Mechanical Engineering, University of Shanghai for Science and Technology, Shanghai 200093, China.
Abstract:
Flexible magnetic-field-based tactile sensors (FMFTS) have numerous advantages including low cost, ease of manufacture, simple wiring, high sensitivity, and so on. Flexible magnetic-field-based tactile sensors need to be calibrated before use to build accurate mapping between contact force and magnetic field intensity measured by magnetic sensors; however, when considering remanence inconsistency of magnetic source, each FMFTS needs to be calibrated independently to enhance accuracy, and the complex preparation prevents FMFTS from being used conveniently. A robust estimation method of contact force and location that can tolerate remanence inconsistency of magnetic source in FMFTS is proposed. Firstly, the position and orientation of magnetic source were tracked using the Levenberg-Marquart algorithm, and the tracking results were insensitive to the remanence of magnetic source with appropriate cost function. Secondly, the mapping between magnitude and location of contact force and position and orientation of magnetic source was built with calibration of one sensor; the mapping only depends on the structural response of flexible substrate, and thus can be extended to estimate external force and location for other sensors with the same structure. The proposed method was evaluated in both simulations and experiments, and the results confirm that the estimation of magnitude and location of external force for FMFTS with the same structure and different remanence could reach acceptable accuracy, depending on single calibration. The proposed method can be used to simplify the calibration procedure and remove the barrier for large-scale application of FMFTS and replacement of damaged FMFTS.
Related Concept Videos
Magnetic Force On A Current-Carrying Conductor
Consider a compass placed near a current-carrying wire. The wire experiences a force that aligns the needle of the compass tangentially around the wire. Thus, the current-carrying wire produces concentric circular loops of magnetic field. The magnetic field generated by a wire can be...
Magnetic Force On Current-Carrying Wires: Example
Magnetic Force
The magnetic force acting on a moving charge...
Magnetic Field Due To A Thin Straight Wire
Magnetic Field Due to Two Straight Wires
Magnetic Force Between Two Parallel Currents
The force exerted by the magnetic field due to the first conductor over a finite length of the second conductor is given as the product of the current in the second conductor and the vector product of the length vector along the current element and the field due to the first conductor. According to the...