Logarithmic Data Processing Can Be Used Justifiably in the Plotting of a Calibration Curve

Dezhao Kong1, Jun Zhao2, Sheng Tang3

  • 1School of Grain Science and Technology, Jiangsu University of Science and Technology, Zhenjiang 212003, Jiangsu Province, PR China.

Analytical Chemistry
|August 30, 2021
PubMed
Summary

Logarithmic data transformation is a valid and essential tool in analytical chemistry for enhancing sensitivity and accuracy. This method simplifies complex data analysis, improving the reliability of quantitative chemical measurements.

Related Concept Videos

Calibration Curves: Linear Least Squares01:20

Calibration Curves: Linear Least Squares

A calibration curve is a plot of the instrument's response against a series of known concentrations of a substance. This curve is used to set the instrument response levels, using the substance and its concentrations as standards. Alternatively, or additionally, an equation is fitted to the calibration curve plot and subsequently used to calculate the unknown concentrations of other samples reliably.
For data that follow a straight line, the standard method for fitting is the linear...
3.2K
Calibration Curves: Correlation Coefficient01:10

Calibration Curves: Correlation Coefficient

In a linear calibration curve, there is a value called the calibration coefficient, denoted by 'r,' which measures the strength and the direction of association between two variables. The correlation coefficient value ranges from −1 to +1. A value of +1 indicates a perfect positive linear correlation, −1 denotes a perfect negative correlation, and 0 implies no correlation between the two variables. A positive correlation value establishes that as one variable increases, the...
3.3K
Instrument Calibration01:12

Instrument Calibration

Instrument calibration is essential for ensuring that instruments produce accurate and consistent results. It is vital in manufacturing, healthcare, testing laboratories, and scientific research. Calibration processes are specific to each instrument and help enhance data accuracy. Each instrument has a unique calibration process tailored to its design and function to improve data accuracy.
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...
354
Plotting and Calibrating the Root Locus01:19

Plotting and Calibrating the Root Locus

Root loci often diverge as system poles shift from the real axis to the complex plane. Key points in this transition are the breakaway and break-in points, indicating where the root locus leaves and reenters the real axis. The branches of the root locus form an angle of 180/n degrees with the real axis, where n is the number of branches at a breakaway or break-in point.
The maximum gain occurs at the breakaway points between open-loop poles on the real axis, while the minimum gain is...
208
Bode Plots01:26

Bode Plots

Bode plots are graphical tools that use logarithmic scales for frequency on the x-axis and gain in decibels on the y-axis. This logarithmic method allows a wide range of frequencies to be compactly displayed, enabling the analysis of component effects on circuit behavior across a broad frequency spectrum.
A network function represents the ratio of a system's output to its input, with the magnitude and phase angle derived from the complex network function. The decibel logarithmic gain is...
929
Design Example: Setting a Curve Using Design Data01:09

Design Example: Setting a Curve Using Design Data

Designing and plotting a curve using field data requires precise calculations and execution. A horizontal curve with a radius of 200 meters and an intersection angle of 20 degrees is established using the method of perpendicular offsets from the long chord. The long chord, which spans between the curve's endpoints, is calculated to be 69.46 meters in length. To maintain accuracy in plotting, intervals of 3 meters are selected along the chord.The engineer determines the offset distances for each...
101