Towards personalized and versatile monitoring of temperature fields within heterogeneous tissues during laser
Jure Kosir1, Daniele Vella1, Matjaz Lukac2,3
1Faculty of Mechanical Engineering, University of Ljubljana, Askerceva 6, Ljubljana, Slovenia.
Abstract:
Advancements in medical laser technology have paved the way for its widespread acceptance in a variety of treatments and procedures. Selectively targeting particular tissue structures with minimally invasive procedures limits the damage to surrounding tissue and allows for reduced post-procedural downtime. In many treatments that are hyperthermia-based, the efficiency depends on the achieved temperature within the targeted tissues. Current approaches for monitoring subdermal temperature distributions are either invasive, complex, or offer inadequate spatial resolution. Numerical studies are often therapy-tailored and source tissue parameters from the literature, lacking versatility and a tissue-specific approach. Here, we show a protocol that estimates the temperature distribution within the tissue based on a thermographic recording of its surface temperature evolution. It couples a time-dependent matching algorithm and thermal-diffusion-based model, while recognizing tissue-specific characteristics yielded by a fast calibration process. The protocol was employed during hyperthermic laser treatment performed ex-vivo on a heterogeneous porcine tissue, and in-vivo on a human subject. In both cases the calibrated thermal parameters correlate with the range of values reported by other studies. The matching algorithm sufficiently reproduced the temperature dynamics of heterogeneous tissue. The estimated temperature distributions within ex-vivo tissue were validated by simultaneous reference measurements, and the ones estimated in-vivo reveal a distribution trend that correlates well with similar studies. The presented method is versatile, supported by the protocol for tissue-specific tailoring, and can readily be implemented for temperature monitoring of various hyperthermia-based procedures by means of recording the surface temperature evolution with a miniature thermal camera implemented within a handheld laser scanner or similar.
More Related Videos
07:47Custom-designed Laser-based Heating Apparatus for Triggered Release of Cisplatin from Thermosensitive Liposomes with Magnetic Resonance Image Guidance
Published on: December 13, 2015
09:01Magnetic-, Acoustic-, and Optical-Triple-Responsive Microbubbles for Magnetic Hyperthermia and Pothotothermal Combination Cancer Therapy
Published on: May 22, 2020
Related Concept Videos
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...