Abstract:
Arterial stiffness (AS) of the carotid artery is an early marker of stratifying cardiovascular disease risk. This article aims to improve the performance of ARTSENS, a noninvasive A-mode ultrasound-based device for measuring AS. The primary objective of ARTSENS is to enable the measurement of elastic modulus using A-Mode ultrasound and blood pressure. As this device is image-free, there is a need to automate: 1) carotid detection; 2) wall localization; and 3) inner lumen diameter measurement. This has been performed using conventional signal processing methods in some of the earlier works in this domain. In this article, deep neural network (DNN) models are employed to perform the above three tasks. The DNNs were trained over data acquired from 82 subjects at two different medical centers. Ground-truth labeling was performed by a trained operator using corresponding measurements from the state-of-the-art Aloka e-Tracking system. All three DNN models had significantly lower errors compared to earlier signal processing methods and could perform their measurements using a single A-Mode frame. Using the DNNs, two different machine learning pipelines have been proposed here to measure the elastic modulus; the best among them could achieve an error of 9.3% with the Pearson correlation coefficient of 0.94 ( ). The models were tested on Raspberry Pi and Jetson Nano single board computers to demonstrate real-time processing on low computational resources.
Related Concept Videos
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Measurement of Blood Pressure
Assessment of blood pressure in brachial artery(two-step method)
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Sites for measruring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...