The Neutron Imaging Instrument CONRAD-Post-Operational Review.
Nikolay Kardjilov1, Ingo Manke1, André Hilger1
1Helmholtz-Zentrum-Berlin, D-14109 Berlin, Germany.
Journal of Imaging
|August 30, 2021
Summary
The CONRAD instrument at BER-II facilitated advanced neutron imaging techniques. Its flexible design and pure cold neutron spectrum expanded the neutron imaging community.
Area of Science:
- Neutron scattering
- Materials science
- Instrument development
Background:
- The CONRAD instrument operated at the BER-II research reactor from 2005 to 2020.
- It utilized neutron flux from the reactor's cold source via a curved neutron guide.
Purpose of the Study:
- To detail the capabilities and impact of the CONRAD neutron imaging instrument.
- To highlight advancements in neutron imaging methodologies enabled by the instrument.
Main Methods:
- Operation of the CONRAD instrument utilizing a pure cold neutron spectrum.
- Employing various neutron optical components like lenses, guides, polarizers, monochromators, and phase gratings.
- Implementing advanced imaging techniques: wavelength-selective, dark-field, phase-contrast, and polarized neutron imaging.
Main Results:
- The instrument's pure cold neutron spectrum facilitated diverse neutron optical components.
- Flexible instrument setup enabled the implementation of novel imaging methods.
- Successful operation attracted scientists and industrial users, fostering community growth.
Conclusions:
- CONRAD's flexible design and advanced capabilities significantly contributed to neutron imaging research.
- The instrument played a key role in expanding the neutron imaging user community.
- Developments at CONRAD advanced the field of neutron imaging applications.
More Related Videos
Related Concept Videos
Nuclear Overhauser Enhancement (NOE)
Irradiation of a spin-active nucleus causes an increase or decrease in the signal intensity of neighboring nuclei that are not necessarily chemically bonded or involved in J-coupling. This phenomenon, called the nuclear Overhauser enhancement (NOE), results from through-space interactions between the nuclear spins. The NOE effect decreases with increasing internuclear distance and is generally not observed beyond 4 angstroms. In NOE, dipole-dipole interactions between neighboring spin-active...
X-ray Imaging
German physicist Wilhelm Röntgen (1845–1923) was experimenting with electrical current when he discovered that a mysterious and invisible "ray" would pass through his flesh but leave an outline of his bones on a screen coated with a metal compound. In 1895, Röntgen made the first durable record of the internal parts of a living human: an "X-ray" image (as it came to be called) of his wife’s hand. Scientists worldwide quickly began their own experiments with X-rays, and by 1900, X-ray was widely...
Positron Emission Tomography
Positron emission tomography (PET) is a medical imaging technique involving radiopharmaceuticals — substances that emit short-lived radiation. Although the first PET scanner was introduced in 1961, it took 15 more years before radiopharmaceuticals were combined with the technique and revolutionized its potential.
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
Atomic Emission Spectroscopy: Instrumentation
The instrumentation of atomic emission spectrometry (AES) involves various components, including atomization devices that convert samples into gas-phase atoms and ions. There are two main types of atomization devices: continuous and discrete atomizers. Continuous atomizers, like plasmas and flames, introduce samples in a constant stream, while discrete atomizers inject individual samples using syringes or autosamplers. The most common discrete atomizer is the electrothermal atomizer.
Insensitive Nuclei Enhanced by Polarization Transfer (INEPT)
Insensitive Nuclei Enhanced by Polarization Transfer (INEPT) is an advanced Nuclear Magnetic Resonance (NMR) technique specifically designed to detect and enhance the signals of low-abundance nuclei, such as carbon-13 and nitrogen-15, in small molecules. The fundamental principle behind INEPT is the transfer of polarization from a more abundant and highly polarizable nucleus, typically hydrogen-1, to the low-abundance nucleus of interest. This process effectively boosts the NMR signal of the...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Positron Emission Tomography (PET) is a medical imaging technique that provides crucial insights into the body's physiological functions at a molecular level. It is an indispensable resource for diagnosing, staging, and monitoring various illnesses, notably cancer, neurological disorders, and cardiovascular conditions.
Fundamental Principles of PET
Fundamental Principles of PET