Pressure Curves, Static and Dynamic Stiffness of Different Two-Component Compression Systems for the Treatment of Chronic Edema of the Lower Limbs
Related Experiment Video
Updated: Oct 22, 2025

Fabrication of Compressed Hosiery and Measurement of its Pressure Characteristic Exerted on the Lower Limbs
Published on: May 27, 2020
Nick Gebruers1,2, Jeroen M H Hendriks2,3,4, Wiebren Tjalma2,3,5
1Department of Rehabilitation Sciences and Physiotherapy (REVAKI-MOVANT), Faculty of Medicine and Health Sciences, University of Antwerp, Antwerp, Belgium.
Abstract:
Compression is a cornerstone modality in edema treatment. Different types of bandages are available in clinical practice. Short-stretch bandages are commonly used; however, newer technologies such as the two-component compression system are available as well. This study assesses the pressure curves and static and dynamic stiffness (Static Stiffness Index [SSI] and Dynamic Stiffness Index [DSI]) of two different two-component compression systems, Coban and CoFlex, for edema treatment. For this prospective cohort study, 12 healthy volunteers were recruited. The healthy volunteers wore both two-component compression systems for 48 hours. Pressure sensors (PicoPress®; Microlab, Italy) were placed at 10 and 25 cm above the internal malleolus and 10 pressure readings were used to obtain pressure curves. The SSI and DSI were assessed. Additionally, comfort (ICC compression questionnaire) and adverse events were assessed as well. Both two-component compression systems exert a sufficient amount of sub-bandage pressure, although CoFlex exerts systematically significantly lower pressure in comparison with Coban. This difference in sub-bandage pressure remains constant over 48 hours. Both two-component compression systems are sufficiently stiff (stiffness >15 mmHg) and remain stiff over time. Both two-component compression systems have pressure curves that are high enough to motivate their use in the treatment of chronic edema. Additionally, both systems were found to be comfortable and have clinically effective SSI and DSI values.
More Related Videos
04:34A Novel Non-invasive Method for the Detection of Elevated Intra-compartmental Pressures of the Leg
Published on: May 31, 2019
07:49Application of Consistent Massage-Like Perturbations on Mouse Calves and Monitoring the Resulting Intramuscular Pressure Changes
Published on: September 20, 2019
Related Concept Videos
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above...
Peripheral Artery Disease V: Postoperative Nursing Management
Residual Stresses in Bending
Dynamic Modulus of Elasticity of Concrete
The sonic test is a common method to determine the dynamic modulus. In this test, a concrete beam, sized either 6 x 6 x 30 inches or 4 x 4 x 20 inches, is clamped at its center. Vibrations are initiated at one end of the beam by an electromagnetic exciter unit powered by...