Related Experiment Video
Updated: Oct 22, 2025

Dynamic Monitoring of Seroconversion using a Multianalyte Immunobead Assay for Covid-19
Published on: February 16, 2022
Liquid Chromatography-Multiple Reaction Monitoring-Mass Spectrometry Assay for Quantitative Measurement of
REGEN-COV is a cocktail of two human IgG1 monoclonal antibodies (REGN10933 + REGN10987) that targets severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) spike protein and has shown great promise to reduce the SARS-CoV-2 viral load in COVID-19 patients enrolled in clinical studies. A liquid chromatography-multiple reaction monitoring-mass spectrometry (LC-MRM-MS)-based method, combined with trypsin and rAspN dual enzymatic digestion, was developed for the determination of total REGN10933 and total REGN10987 concentrations in several hundreds of pharmacokinetic (PK) serum samples from COVID-19 patients participating in phase I, II, and III clinical studies. The performance characteristics of this bioanalytical assay were evaluated with respect to linearity, accuracy, precision, selectivity, specificity, and analyte stability before and after enzymatic digestion. The developed LC-MRM-MS assay has a dynamic range from 10 to 2000 μg/mL antibody drug in the human serum matrix, which was able to cover the serum drug concentration from day 0 to day 28 after drug administration in two-dose groups for the clinical PK study of REGEN-COV. The concentrations of REGEN-COV in the two-dose groups measured by the LC-MRM-MS assay were comparable to the concentrations measured by a fully validated electrochemiluminescence (ECL) immunoassay.
REGEN-COV is a cocktail of two human IgG1 monoclonal antibodies (REGN10933 + REGN10987) that targets severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) spike protein and has shown great promise to reduce the SARS-CoV-2 viral load in COVID-19 patients enrolled in clinical studies. A liquid chromatography-multiple reaction monitoring-mass spectrometry (LC-MRM-MS)-based method, combined with trypsin and rAspN dual enzymatic digestion, was developed for the determination of total REGN10933 and total REGN10987 concentrations in several hundreds of pharmacokinetic (PK) serum samples from COVID-19 patients participating in phase I, II, and III clinical studies. The performance characteristics of this bioanalytical assay were evaluated with respect to linearity, accuracy, precision, selectivity, specificity, and analyte stability before and after enzymatic digestion. The developed LC-MRM-MS assay has a dynamic range from 10 to 2000 μg/mL antibody drug in the human serum matrix, which was able to cover the serum drug concentration from day 0 to day 28 after drug administration in two-dose groups for the clinical PK study of REGEN-COV. The concentrations of REGEN-COV in the two-dose groups measured by the LC-MRM-MS assay were comparable to the concentrations measured by a fully validated electrochemiluminescence (ECL) immunoassay.
More Related Videos
07:08A Rapid, Multiplex Dual Reporter IgG and IgM SARS-CoV-2 Neutralization Assay for a Multiplexed Bead-Based Flow Analysis System
Published on: April 6, 2021
11:09An HS-MRM Assay for the Quantification of Host-cell Proteins in Protein Biopharmaceuticals by Liquid Chromatography Ion Mobility QTOF Mass Spectrometry
Published on: April 17, 2018