Observational Study Protocol for Repeated Clinical Examination and Critical Care Ultrasonography Within the Simple Intensive Care Studies
Published on: January 16, 2019
Automated versus manual urine output monitoring in the intensive care unit
Joni Minor1, Ali Smith2, Frederic Deutsch3
1University of Pittsburgh Medical Center (UPMC), Pittsburgh, PA, USA.
Abstract:
Acute kidney injury (AKI) is defined by changes in serum creatinine and urine output (UO). Significant limitations exist regarding accurate ascertainment of urine output even within the intensive care unit. We sought to evaluate an automated urine output collections system and compare it to nursing measurements. We prospectively collected urine output using an electronic urine monitoring system and compared it to charted hourly UO in 44 patients after cardiac surgery at a single university hospital ICU. We calculated UO and oliguria rates and compared them to data from the sensor and from nursing charting. A total of 187 hourly UO measurements were obtained and on average, UO was reported 47 min late, with a median of 18 min, and a maximum of almost 6 h. Patients had a mean hourly UO of 76.3 ml over the observation period. Compared to manual measurements by study personnel, nurses significantly overestimated hourly UO by 19.9 ml (95% CI: 10.3; 29.5; p = < 0.001). By contrast, the mean difference between the UO measured with the sensor and by study personnel was 2.29 ml (95% CI: - 6.7; 11.3), p = 0.61. Electronic UO monitoring is significantly more accurate than nurse-performed manual measurements in actual intensive care patients. Furthermore, timely ascertainment of UO is difficult to achieve with manual technique, resulting in important delays in detecting oliguria perhaps leading to missed cases of AKI.
Related Concept Videos
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Peritoneal Dialysis II: Peritoneal Dialysis Systems and Complications
Continuous Renal Replacement Therapy
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Acute Kidney Injury IV: Diagnostic Studies and Prevention
Urodynamic Studies: Uroflowmetry