Visual outcome and optical quality of a wavefront-engineered extended depth-of-focus intraocular lens
Daria Greve1, Eckart Bertelmann, Daniel Pilger
1From the Department of Ophthalmology, Vivantes Neukölln, Berlin, Germany (Greve); Department of Ophthalmology, Charité-Medical University, Berlin, Germany (Bertelmann, Pilger, von Sonnleithner).
Purpose:
To evaluate visual performance and optical quality of an extended depth-of-focus intraocular lens (EDoF IOL) compared with a monofocal aspheric IOL.
Setting:
Department of Ophthalmology, Charité-Medical University Berlin, Germany.
Design:
Prospective case series.
Methods:
After phacoemulsification, a total of 28 patients (56 eyes) underwent bilateral implantation of either the Mini Well (EDoF IOL) or the Mini 4 (monofocal IOL). Assessments including refraction, distance, intermediate and near visual acuity, defocus curves, contrast sensitivity, glare disability, higher-order aberrations (HOAs), and patient satisfaction were performed at 1 month and 3 months postoperatively.
Results:
Both study groups comprised 14 patients (28 eyes) each. At 3-month follow-up, the EDoF IOL showed better results in monocular uncorrected intermediate visual acuity (-0.04 vs 0.10 logMAR, P = .000) and in uncorrected near visual acuity (0.13 vs 0.36 logMAR, P = .000), whereas no statistically significant difference was found between groups in monocular uncorrected distance visual acuity (0.04 vs 0.00 logMAR, P = .110). The monocular depth of focus was 0.8 D greater in the Mini Well IOL group. Measurements of internal HOAs revealed a greater negative primary spherical aberration in the EDoF group at pupil sizes of 2.0 to 5.0 mm. At 5.0 mm, total internal HOAs did not differ statistically significantly (0.376 vs 0.340 μm root mean square, P = .068).
Conclusions:
The Mini Well IOL provided greater depth of focus with superior outcomes at intermediate and near distances and comparable outcomes at far distance. Although inducing higher amounts of spherical aberration, it showed good results under low lighting conditions with little subjective dysphotopsia.
More Related Videos
07:12Spatio-Temporal In Vivo Imaging of Ocular Drug Delivery Systems using Fiberoptic Confocal Laser Microendoscopy
Published on: September 27, 2021
06:55Scanning Light Scattering Profiler SLPS Based Methodology to Quantitatively Evaluate Forward and Backward Light Scattering from Intraocular Lenses
Published on: June 6, 2017
Related Concept Videos
Focusing of Light in the Eye
Imaging Biological Samples with Optical Microscopy
In optical microscopy, the specimen to be viewed is placed on a glass slide and clipped on the stage...
Angle Closure Glaucoma: Treatment
Open Angle Glaucoma: Treatment
Drugs such as carbonic anhydrase inhibitors, α2- and...