Related Experiment Video
Updated: Oct 4, 2026

Developing a Salivary Antibody Multiplex Immunoassay to Measure Human Exposure to Environmental Pathogens
Published on: September 12, 2016
Pulse immunoassay for human immunoglobulin G using antibody bound latex beads
E Tamiya1, N Watanabe, H Matsuoka
1Research Laboratory of Resources Utilization, Tokyo Institute of Technology, Yokohama, Japan.
Pulse immunoassay was applied in the immunoassay of human immunoglobulin G (H-IgG). Antibodies to H-IgG were covalently immobilized on the surface of latex beads (1 microM). Immunoreaction of the antibody bound latex beads (Ab-L) and H-IgG was performed using electric pulses. Agglutination rate (AR), defined by the following equation, was used to estimate the immunoreaction rate (formula; see text) where Nn is the total number of beads forming n bead agglutinations. Each Nn was determined by analyzing photographs of the samples. When 140 microliter of Ab-L suspension (0.7%) containing H-IgG (6.7 X 10(-6) g ml-1) was reacted using electric pulses (peak height 2 kV cm-1, pulse width 20 microseconds, pulse frequency 8 kHz), AR increased sharply and reached 50% after 10 min. In contrast, when the same sample was reacted without electric pulses, AR increased very slowly and only reached 20% after 20 min. Therefore, the immunoreaction of H-IgG and Ab-L can be carried out more rapidly by applying electric pulses.
Pulse immunoassay was applied in the immunoassay of human immunoglobulin G (H-IgG). Antibodies to H-IgG were covalently immobilized on the surface of latex beads (1 microM). Immunoreaction of the antibody bound latex beads (Ab-L) and H-IgG was performed using electric pulses. Agglutination rate (AR), defined by the following equation, was used to estimate the immunoreaction rate (formula; see text) where Nn is the total number of beads forming n bead agglutinations. Each Nn was determined by analyzing photographs of the samples. When 140 microliter of Ab-L suspension (0.7%) containing H-IgG (6.7 X 10(-6) g ml-1) was reacted using electric pulses (peak height 2 kV cm-1, pulse width 20 microseconds, pulse frequency 8 kHz), AR increased sharply and reached 50% after 10 min. In contrast, when the same sample was reacted without electric pulses, AR increased very slowly and only reached 20% after 20 min. Therefore, the immunoreaction of H-IgG and Ab-L can be carried out more rapidly by applying electric pulses.
Related Concept Videos
Immunoprecipitation
Chromatin Immunoprecipitation
Chromatin immunoprecipitation, also known as ChIP, is used to study protein-DNA or...
Enzyme-Linked Immunosorbent Assay
There are many different types of ELISAs, but they all involve an antibody molecule whose constant region binds an enzyme, leaving the variable region free to bind its specific antigen. Enzyme-substrate reaction allows the antigen to be visualized or quantified.

