Related Experiment Video
Updated: Oct 21, 2025

Continuous Venous-Arterial Doppler Ultrasound During a Preload Challenge
Published on: January 20, 2023
Ability of short-time low peep challenge to predict fluid responsiveness in mechanically ventilated patients in the
Taner Abdullah1,2, Achmet Ali3, Esra Saka3
1Department of Anesthesiology, Basaksehir Cam and Sakura City Hospital, Basaksehir Mah. G-434 Cad. No: 2L Basaksehir, Istanbul, Turkey. taner.abdullah@gmail.com.
Abstract:
Short-time low PEEP challenge (SLPC, application of additional 5 cmH2O PEEP to patients for 30 s) is a novel functional hemodynamic test presented in the literature. We hypothesized that SLPC could predict fluid responsiveness better than stroke volume variation (SVV) in mechanically ventilated intensive care patients. Heart rate, mean arterial pressure, stroke volume index (SVI) and SVV were recorded before SLPC, during SLPC and before and after 500 mL fluid loading. Patients whose SVI increased more than 15% after the fluid loading were defined as fluid responders. Reciever operating characteristics (ROC) curves were generated to evaluate the abilities of the methods to predict fluid responsiveness. Fifty-five patients completed the study. Twenty-five (46%) of them were responders. Decrease percentage in SVI during SLPC (SVIΔ%-SLPC) was 11.6 ± 5.2% and 4.3 ± 2.2% in responders and non-responders, respectively (p < 0.001). A good correlation was found between SVIΔ%-SLPC and percentage change in SVI after fluid loading (r = 0.728, P < 0.001). Areas under the ROC curves (ROC-AUC) of SVIΔ%-SLPC and SVV were 0.951 (95% CI 0.857-0.991) and 0.747 (95% CI 0.611-0.854), respectively. The ROC-AUC of SVIΔ%-SLPC was significantly higher than that of SVV (p = 0.0045). The best cut-off value of SVIΔ%-SLPC was 7.5% with 90% sensitivity and 96% specificity. The percentage change in SVI during SLPC predicts fluid responsiveness in intensive care patients who are ventilated with low tidal volumes; the sensitivity and specificity values are higher than those of SVV.
More Related Videos
05:56Monitoring Lung Function with Electrical Impedance Tomography in the Intensive Care Unit
Published on: September 6, 2024
06:22Surfactant Depletion Combined with Injurious Ventilation Results in a Reproducible Model of the Acute Respiratory Distress Syndrome ARDS
Published on: April 7, 2021
Related Concept Videos
Mechanical Ventilation I: Indication and Settings
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Ventilatory Modes
There are three ventilatory modes: full support, partial support, and spontaneous. These are described below.
Full Support Modes
Full support modes include controlled mechanical ventilation, continuous mandatory...
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation...
Cardiopulmonary Resuscitation II: ACLS Airway Management