Related Experiment Video
Updated: Oct 21, 2025

Tracking the Mammary Architectural Features and Detecting Breast Cancer with Magnetic Resonance Diffusion Tensor Imaging
Published on: December 15, 2014
BI-RADS 3 on dense breast screening ultrasound after digital mammography versus digital breast tomosynthesis
Elizabeth H Dibble1, Tisha M Singer1, Grayson L Baird2
1Department of Diagnostic Imaging, The Warren Alpert Medical School of Brown University/Rhode Island Hospital, United States of America.
Objective:
Compare the BI-RADS 3 rate and follow-up of dense breast ultrasound (US) screening following digital mammography (DM) versus digital breast tomosynthesis (DBT).
Methods:
IRB-approved, HIPAA compliant retrospective search was performed of databases at two tertiary breast centers and an office practice for BI-RADS 3 screening US examinations performed 10/1/14-9/30/16. Prior DM versus DBT, downgrade and upgrade rate, and timing and pathology results were recorded. Differences were compared using the two-sample proportions test.
Results:
3183 screening US examinations were performed, 1434/3183 (45.1%) after DM and 1668/3183 (52%) after DBT (2.5% (81/3183) no prior mammogram available). 13.9% (199/1434) had BI-RADS 3 results after DM and 10.6% (177/1668) after DBT (p < 0.01). Median imaging follow-up after DM was 12 months (IQR 6, 24) versus 18 after DBT (IQR 11, 25), p = 0.02. 19.5% (73/375) of patients were lost to follow-up (19.2% (38/198) after DM (68.4% (26/38) no follow-up after initial exam) versus 19.8% (35/177) after DBT (54.3% (19/35) no follow-up after initial exam). 1.3% (5/375) of patients elected biopsy (1.5% (3/198) after DM and 1.1% (2/177) after DBT). 75.2% (282/375) of patients were downgraded (75.3% (149/198) after DM and 75.1% (133/177) after DBT). 2.5% (5/198) were upgraded after DM and 0.6% (1/177) after DBT. Median time to upgrade was 6 months after both DM and DBT. 0.3% (1/375) of patients with BI-RADS 3 results had cancer on follow-up.
Conclusion:
Patients with prior DBT had a lower risk of encountering BI-RADS 3 findings on screening ultrasound. BI-RADS 3 findings on screening ultrasound had an extremely low rate of being cancer.
More Related Videos
12:23Multi-modal Imaging of Angiogenesis in a Nude Rat Model of Breast Cancer Bone Metastasis Using Magnetic Resonance Imaging, Volumetric Computed Tomography and Ultrasound
Published on: August 14, 2012
09:02Cortical Bone Assessment Using Ultrasonic Guided Waves: A Reproducibility Study in a Healthy Population
Published on: January 31, 2025
Related Concept Videos
Imaging Studies III: Computed Tomography
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Radiological Investigation I: X-ray and CT
X-ray Imaging