Abstract:
The aims of the present prospective clinical study were to determine objective, sensor-measured adherence to a mandibular advancement device (MAD) in patients with obstructive sleep apnea (OSA) and to identify partner-specific adherence-related factors. A total of 77 eligible participants with mild, moderate, or severe OSA and who were non-adherent to continuous positive airway pressure (mean age 56.2 years) participated in the study (32.5% women). The mean (range) observation time between MAD delivery and final follow-up was 8.3 (3.4-16.5) months. The mean apnea-hypopnea index (AHI) was 26.6 events/hr at baseline and 12.5 events/hr at the 8-month follow-up (both p < 0.001). The mean sensor-measured adherence at the 8-month follow-up was 60.1% for ≥4 hr/night of appliance use for ≥5 days/week. Average usage was 6.4 hr/night, when worn. The mean reduction in the AHI was significantly greater in the "good adherence" (Δ 17.4) than the "poor adherence" group (Δ11.0; p < 0.05). From the partner's perspective, the appliance had a positive effect on sharing a bedroom in the good- (55%) compared to the poor-adherence group (25%; p < 0.05) and on their relationship (51.7% versus 17.9%, respectively; p < 0.05). Regression analyses identified the partner's snoring and apneas to be the most significant factor predicting good adherence to MAD (odds ratio 4.4, 95% confidence interval 1.4-14.0). In conclusion, social factors, like partner perceptions, were positively associated with adherence, which indicate that partner's attitudes and support may be a resource that can be utilised to improve adherence in oral appliance treatment of OSA.
Related Concept Videos
Sleep Apnea
The condition is more prevalent among...
Blind Procedures
Factors Affecting Perception
An illustrative example of a perceptual set is the scenario where an airline pilot told...
Obedience
Respiratory Assessment: Purpose and Indications
Objectives and Importance:
The primary goal of respiratory assessment is to evaluate patients at early risk of clinical deterioration. Since respiratory distress often precedes other signs of declining health, breathing patterns and sounds become a...
Assessment of Airway, Skin Color, and Use of Accessory Muscles
Introduction
The initial evaluation of a patient's respiratory system...