Systematic Evaluation of Liquid Chromatography (LC) Column Combinations for Application in Two-Dimensional LC
Maria Grübner1,2, Andreas Dunkel1,3, Frank Steiner2
1Chair of Food Chemistry and Molecular Sensory Science, Technical University of Munich, Lise-Meitner-Straße 34, Freising 85354, Germany.
Abstract:
In comparison to proteomics, the application of two-dimensional liquid chromatography (2D LC) in the field of metabolomics is still premature. One reason might be the elevated chemical complexity and the associated challenge of selecting proper separation conditions in each dimension. As orthogonality of dimensions is a major issue, the present study aimed for the identification of successful stationary phase combinations. To determine the degree of orthogonality, first, six different metrics, namely, Pearson's correlation coefficient (1 - |R|), the nearest-neighbor distances (H̅NND), the "asterisk equations" (AO), and surface coverage by bins (SCG), convex hulls (SCCH), and α-convex hulls (SCαH), were critically assessed by 15 artificial 2D data sets, and a systematic parameter optimization of α-convex hulls was conducted. SGG, SCαH with α = 0.1, and H̅NND generated valid results with sensitivity toward space utilization and data distribution and, therefore, were applied to pairs of experimental retention time sets obtained for >350 metabolites, selected to represent the chemical space of human urine. Normalized retention data were obtained for 23 chromatographic setups, comprising reversed-phase (RP), hydrophilic interaction liquid chromatography (HILIC), and mixed-mode separation systems with an ion exchange (IEX) contribution. As expected, no single LC setting provided separation of all considered analytes, but while conventional RP×HILIC combinations appeared rather complementary than orthogonal, the incorporation of IEX properties into the RP dimension substantially increased the 2D potential. Eventually, one of the most promising column combinations was implemented for an offline 2D LC time-of-flight mass spectrometry analysis of a lyophilized urine sample. Targeted screening resulted in a total of 164 detected metabolites and confirmed the outstanding coverage of the 2D retention space.
More Related Videos
11:00Untargeted Metabolomics from Biological Sources Using Ultraperformance Liquid Chromatography-High Resolution Mass Spectrometry UPLC-HRMS
Published on: May 20, 2013
14:42Liquid Chromatography Coupled to Refractive Index or Mass Spectrometric Detection for Metabolite Profiling in Lysate-based Cell-free Systems
Published on: September 23, 2021
Related Concept Videos
Principles Of Column Chromatography
High-Performance Liquid Chromatography: Elution Process
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
Types Of Column Chromatography
Gel Filtration Chromatography
When the...
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
Chromatographic Methods: Classification
Chromatographic techniques are typically named by...